Siemens 3RV5031-4DA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV5031-4DA10 SIRIUS Motor Protection CB, 25 A, Clas

MPN3RV5031-4DA10

Siemens SIRIUS 3RV5031-4DA10, motor protection circuit breaker, S2 frame, 3-pole, 25 A rated operational current, Trip Class 10, screw-type terminals, 690 V max, 50/60 Hz.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV5031-4DA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2
3RV5031-4DA10 — Electrical
ParameterValue
Rated operational current (Ie)25 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV5031-4DA10 — Protection & Tripping
ParameterValue
Overload release setting range18 ... 25 A
Instantaneous short-circuit trip current325 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
3RV5031-4DA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals with box terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.75 ... 25 mm²), 1x (0.75 ... 35 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.75 ... 16 mm²), 1x (0.75 ... 25 mm²)
Conductor range, AWG (main contacts)2x (18 ... 2), 1x (18 ... 2)
3RV5031-4DA10 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022
Mounting positionany
3RV5031-4DA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV5031-4DA10 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

It carries a 25 A rated operational current and delivers 25 A in AC-3 duty at 400 V, with a Trip Class 10 thermal release that matches standard motor start-up profiles — meaning it will hold through a normal start but trip before the winding overheats on a stalled rotor.

The S2 frame footprint is 55 mm wide, 140 mm tall, 149 mm deep — plan for that depth behind the panel door. Clearance requirements: 50 mm above and below, 30 mm to the side, 140 mm forward; zero clearance needed behind the rail. Screw-type box terminals on top and bottom accept up to 35 mm² solid or 25 mm² fine-stranded with ferrules; torque to 3–4.5 N·m.

Electrical Ratings and Environment

Rated for 690 V maximum (AC-3), 50/60 Hz, with a surge voltage resistance of 6 kV. Total typical power loss is 12 W. Relative humidity tolerance is 10 to 95 %. Shock resistance per IEC 60068-2-27 is 25 g for 11 ms. Maximum installation altitude is 2000 m above sea level. Maximum operating frequency in AC-3 duty is 15 operations per hour.

Frequently asked questions

How do I get current pricing and availability for 3RV5031-4DA10?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current pricing and availability at the time of your order.

What is the closest functional second-source to 3RV5031-4DA10?

The 3RV6021-4DA10 is a peer in the same SIRIUS motor protection family. The key difference is the frame size — 3RV5031-4DA10 is an S2 frame, while 3RV6021-4DA10 is an S0 frame. The S0 frame is physically smaller (45 mm wide vs 55 mm), so a panel cut out for the S2 will have extra width if you swap to the S0. Both are 3-pole, Class 10, and use screw terminals, but verify the current rating and terminal wire range on the specific variant before substituting.