Siemens 3RV5431-4FA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV5431-4FA10 SIRIUS Circuit Breaker, 40 A, Class 10

MPN3RV5431-4FA10

Siemens SIRIUS circuit breaker, 3RV5431-4FA10, for transformer protection, 40 A rated operational current, Class 10 trip, 690 V, 3-pole, screw terminals, S2 frame, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV5431-4FA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS2
3RV5431-4FA10 — Electrical
ParameterValue
Rated operational current (Ie)40 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV5431-4FA10 — Protection & Tripping
ParameterValue
Overload release setting range28 ... 40 A
Instantaneous short-circuit trip current836 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
3RV5431-4FA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals with box terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.75 ... 25 mm²), 1x (0.75 ... 35 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.75 ... 16 mm²), 1x (0.75 ... 25 mm²)
3RV5431-4FA10 — Mechanical
ParameterValue
Height140 mm
Width55 mm
Depth149 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022
Mounting positionany
3RV5431-4FA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV5431-4FA10 — Specifications
ParameterValue
Design Of The Productfor transformer protection

Product details

The Siemens 3RV5431-4FA10 is a SIRIUS circuit breaker specifically designed for transformer protection, carrying a 40 A rated operational current at 400 V AC-3 and a 690 V rated insulation voltage. This is the part you spec when a motor-starting curve is too slow and a standard thermal-magnetic would trip on the magnetizing inrush.

The S2 frame (55 mm wide, 140 mm tall, 149 mm deep) needs 50 mm clearance above and below, 140 mm forward, and 30 mm to the side — no clearance needed behind the rail. Box terminals accept 2x 0.75–25 mm² solid/stranded or 1x up to 35 mm²; torque to 3–4.5 N·m.

Operates from -20 to +60 °C with 10–95 % relative humidity; survives transport down to -50 °C. Rated for installation up to 2000 m above sea level and withstands 25 g / 11 ms shock per IEC 60068-2-27. The substance prohibitance date of 07/01/2006 indicates RoHS compliance ahead of the EU directive.

The 40 A rating at AC-3 (400 V) governs motor and transformer switching duty — that is the current it can make and break under load. Power loss is 20 W typical, which matters for thermal management inside a sealed enclosure. The thermal overload release handles sustained overloads; the magnetic short-circuit trip clears faults fast. Operating frequency is 50–60 Hz; at AC-3 duty the maximum switching rate is 15 operations per hour.

Frequently asked questions

What is the closest functional second-source for 3RV5431-4FA10?

The 3RV6021-4DA10 is a peer within the SIRIUS family, but the 3RV5431-4FA10 is specifically designed for transformer protection with a Class 10 trip, while the 3RV6021-4DA10 may have different trip characteristics or frame size. Verify the trip class and current rating against your load before substituting.

MPN
3RV5431-4FA10