Siemens 3RV6011-0CA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV6011-0CA10 SIRIUS Motor Protection CB, 0.25 A, Cl

MPN3RV6011-0CA10

Siemens SIRIUS 3RV6011-0CA10, size S00 motor protection circuit breaker, 3-pole, 0.25 A rated operational current, Class 10 trip, screw terminals, 45 mm width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV6011-0CA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV6011-0CA10 — Electrical
ParameterValue
Rated operational current (Ie)0.25 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV6011-0CA10 — Protection & Tripping
ParameterValue
Overload release setting range0.18 ... 0.25 A
Instantaneous short-circuit trip current3.3 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
3RV6011-0CA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 to 12), 2x (20 to 16)
3RV6011-0CA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV6011-0CA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV6011-0CA10 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Panel integration — DIN footprint and clearances

The 3RV6011-0CA10: Width 45 mm, depth 96 mm, height 97 mm. Any mounting position. Clearance: 50 mm upwards, 50 mm downwards, 30 mm at the side, 0 mm forwards and backwards. Panel-builder note: the 0 mm forward/backward clearance means it sits flush against the backplane or enclosure wall — no breathing gap needed for this frame size. Screw terminal torque: 0.8 to 1.2 N·m.

Frequently asked questions

What are the key ratings for 3RV6011-0CA10?

Rated operational current 0.25 A at AC-3 / 400 V, Trip Class 10, rated insulation voltage 690 V, operating frequency 50/60 Hz, surge voltage resistance 6 kV, power loss 5 W total typical.

Will 3RV6011-0CA10 drop into a panel specified around 3RV1011-0GA10?

Both are size S00, 45 mm wide, 3-pole, screw terminals, same DIN rail footprint and clearance requirements. The 3RV6011-0CA10 is the standard-duty SIRIUS line; the 3RV1011-0GA10 is the high-performance variant with higher breaking capacity. Panel cutout and wiring are identical, but verify the available fault current at the panel — the 3RV1011 series carries a higher short-circuit breaking rating.

Where can I buy 3RV6011-0CA10?

Sourced and quoted to order against an RFQ through independent industrial distribution. Availability and current pricing confirmed at quote time.

MPN