Siemens 3RV6011-0CA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV6011-0CA15 SIRIUS Motor Protection Circuit Breake

MPN3RV6011-0CA15

Siemens SIRIUS 3RV6011-0CA15, motor protection circuit breaker, size S00, 3-pole, 0.25 A rated current, Trip Class 10, 690 V AC-3, screw terminals, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RV6011-0CA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV6011-0CA15 — Electrical
ParameterValue
Rated operational current (Ie)0.25 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV6011-0CA15 — Protection & Tripping
ParameterValue
Overload release setting range0.18 ... 0.25 A
Instantaneous short-circuit trip current3.3 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
3RV6011-0CA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 to 12), 2x (20 to 16)
3RV6011-0CA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV6011-0CA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV6011-0CA15 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens 3RV6011-0CA15 is a SIRIUS motor protection circuit breaker, size S00, with a rated operational current of 0.25 A and Trip Class 10.

At 0.25 A rated current, this breaker is sized for very small motors or control transformers; verify your motor's full-load amps against the 0.25 A rating before specifying. The 3-pole design interrupts all three phases simultaneously. Clearance requirements: 50 mm above and below, 30 mm to the side, 0 mm forward/backward — plan your gland plate and wire bend radius accordingly.

The 3RV6011-0CA15 carries a RoHS compliance date of 05/01/2012, indicating it meets EU RoHS requirements. No UL or CSA listing is explicitly stated in the evidence, but the IEC ratings (690 V, 50/60 Hz, shock 25g/11 ms per IEC 60068-2-27) are standard for global panel builds.

Frequently asked questions

Will 3RV6011-0CA15 drop into a panel specified around 3RV6011-0CA10 without rewiring?

Both are size S00, 3-pole, screw-terminal motor protection breakers with the same 45 mm width and DIN-rail mounting. The 3RV6011-0CA10 carries a different current rating; verify your motor's FLA against the 0.25 A rating of the -0CA15 before substitution.

MPN
3RV6011-0CA15