Skip to main content
Siemens 3RV6011-0DA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV6011-0DA10 SIRIUS Motor Protection Circuit Breake

MPN3RV6011-0DA10

Siemens SIRIUS 3RV6011-0DA10 motor protection circuit breaker, size S00, 0.32 A rated operational current, Class 10 trip, 690 V, 50/60 Hz, screw-type terminals, DIN-rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RV6011-0DA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV6011-0DA10 — Electrical
ParameterValue
Rated operational current (Ie)0.32 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV6011-0DA10 — Protection & Tripping
ParameterValue
Overload release setting range0.22 ... 0.32 A
Instantaneous short-circuit trip current4.2 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
3RV6011-0DA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 to 12), 2x (20 to 16)
3RV6011-0DA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV6011-0DA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV6011-0DA10 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens 3RV6011-0DA10 is a SIRIUS motor protection circuit breaker in the S00 frame size, rated at 0.32 A operational current with a Class 10 trip characteristic. It protects motors against overload (thermal release) and short-circuit (magnetic release) in a single device, sized for small fractional-horsepower loads on 50/60 Hz systems up to 690 V.

The S00 footprint — 45 mm wide, 97 mm tall, 96 mm deep — fits standard panel layouts; clearance requirements are 50 mm above and below, 30 mm to the side, and zero forward/backward clearance needed.

The 0.32 A AC-3 rating at 400 V is the motor-switching current — this breaker is sized for a very small motor (roughly 0.12 kW at 400 V three-phase). The 690 V rated insulation voltage covers most industrial supply voltages, and the 6 kV rated surge voltage resistance ensures coordination with typical distribution panels.

Frequently asked questions

What is the closest functional alternative to 3RV6011-0DA10?

The 3RV6011-0CA10 is a direct peer in the same S00 frame and Class 10 trip, but with a different rated current — verify your motor's FLA before substituting. The 3RV6011-0DA10 drops into the same DIN-rail footprint and wiring scheme as the 3RV6011-0CA10 without panel modifications.

Where can I buy 3RV6011-0DA10?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability.

What compliance documentation does 3RV6011-0DA10 carry?

The part is RoHS compliant with a substance prohibition date of May 1, 2012. Additional compliance documentation (UL, IEC) is available from the manufacturer upon request.

MPN
3RV6011-0DA10