3RV6011-0EA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV6011-0EA15 — Electrical
ParameterValue
Rated operational current (Ie)0.4 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV6011-0EA15 — Protection & Tripping
ParameterValue
Overload release setting range0.28 ... 0.4 A
Instantaneous short-circuit trip current5.2 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
3RV6011-0EA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 to 12), 2x (20 to 16)
3RV6011-0EA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV6011-0EA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV6011-0EA15 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

It combines a thermal overload relay (Class 10) and a magnetic short-circuit release in one compact 45 mm wide housing. Rated at 0.4 A operational current on a 690 V AC, 50/60 Hz system, it provides coordinated motor branch protection in control panels. The 96 mm depth fits standard shallow enclosures; 45 mm width occupies one standard module slot.

The 0.4 A rated operational current (at AC-3 duty, 690 V max) sets the motor FLA this breaker protects. AC-3 is the standard motor-switching category (squirrel-cage motors, starting and switching off during running). The operating frequency is capped at 15 switching cycles per hour — fine for typical pump or fan duty; not for high-cycling applications like rapid indexing. Total typical power loss is 5 W at rated current. Terminals accept 2× (0.5 to 1.5 mm²) solid/stranded or 2× (0.75 to 2.5 mm²) for the main circuit; auxiliary contacts use 2× (0.5 to 1.5 mm²) or 2× (0.75 to 2.5 mm²) finely stranded with ferrules. AWG equivalents: main 2× (18 to 12) or 2× (20 to 16); auxiliary 2× (20 to 16) or 2× (18 to 14). Torque for main screw terminals: 0.8 to 1.2 N·m.

Panel Integration & Wiring

Shock resistance: 25 g for 11 ms per IEC 60068-2-27.

Frequently asked questions

When sourcing 3RV6011-0EA15, what's the closest functional second-source — 3RV1011-0GA10?

The 3RV1011-0GA10 is a peer in the same SIRUS motor protection breaker family but in the larger S0 frame size. The 3RV6011-0EA15 (S00 frame) is physically smaller — 45 mm wide vs the S0's wider footprint — and has a different mounting hole pattern. It will not drop into a panel wired for the S0 frame without a new DIN rail arrangement and possibly different terminal spacing. For a direct functional match, stay within the S00 frame; the 3RV1011 series is a different mechanical fit.

What is 3RV6011-0EA15's listed depth (96 mm) on this component line?

The depth is 96 mm. Combined with the 45 mm width and 97 mm height, it fits standard shallow enclosures.

MPN
3RV6011-0EA15