Skip to main content
Siemens 3RV6011-0GA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV6011-0GA10 SIRIUS Motor Protection Circuit Breake

MPN3RV6011-0GA10

Siemens SIRIUS motor protection circuit breaker, 3RV6011-0GA10, Size S00, 0.63 A rated operational current, Class 10, 3-pole, screw terminals, snap-on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV6011-0GA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV6011-0GA10 — Electrical
ParameterValue
Rated operational current (Ie)0.63 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV6011-0GA10 — Protection & Tripping
ParameterValue
Overload release setting range0.45 ... 0.63 A
Instantaneous short-circuit trip current8.2 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
3RV6011-0GA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 to 12), 2x (20 to 16)
3RV6011-0GA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV6011-0GA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV6011-0GA10 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens 3RV6011-0GA10 is a SIRIUS motor protection circuit breaker in the Size S00 frame, rated 0.63 A operational current with a thermal overload release (Class 10) and a magnetic short-circuit trip. It protects three-phase motors up to that current on 50/60 Hz supplies up to 690 V AC-3.

The 0.63 A rated operational current at AC-3 (400 V) is the motor-load switching rating — this breaker is sized for a small motor, fractional-horsepower pump or fan, not a 5 kW drive. The 5 W total power loss is low enough that no forced cooling is needed inside a sealed panel. The screw terminals accept 2x (0.75 to 2.5 mm²) solid or stranded, or 2x 4 mm², with a torque range of 0.8 to 1.2 N·m. That covers standard motor feeder wiring up to about 14 AWG.

Frequently asked questions

What is the closest functional second-source to 3RV6011-0GA10?

The 3RV6021-4DA10 is a larger-frame Size S2 breaker rated for higher currents — it will not drop into a panel wired for the S00 frame without rewiring and a larger DIN footprint. The 3RV2011-0AA10 is a closer Size S00 peer but check its trip class and terminal configuration against your BOM.

What is the width and depth of 3RV6011-0GA10?

Width is 45 mm, depth is 96 mm, height is 97 mm. Clearance above and below is 50 mm each side, 30 mm to the sides.

Where can I buy 3RV6011-0GA10?

Sourced to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.

MPN
3RV6011-0GA10