Siemens 3RV6011-0GA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV6011-0GA15 SIRIUS Motor Protection Circuit Breake

MPN3RV6011-0GA15

Siemens SIRIUS 3RV6011-0GA15, motor protection circuit breaker, size S00, 3-pole, 0.63 A rated operational current, Class 10 trip, screw terminals, 690 V, 50/60 Hz, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV6011-0GA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV6011-0GA15 — Electrical
ParameterValue
Rated operational current (Ie)0.63 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV6011-0GA15 — Protection & Tripping
ParameterValue
Overload release setting range0.45 ... 0.63 A
Instantaneous short-circuit trip current8.2 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
3RV6011-0GA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 to 12), 2x (20 to 16)
3RV6011-0GA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV6011-0GA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV6011-0GA15 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor Protection Circuit Breaker for 0.63 A Loads

The Siemens 3RV6011-0GA15 is a SIRIUS motor protection circuit breaker in size S00, designed to protect a 0.63 A motor load in a 3-phase circuit up to 690 V at 50/60 Hz. The magnetic short-circuit release handles fault interruption without relying on upstream fuses for motor branch circuits within its rated breaking capacity.

Main circuit screw terminals accept 2× (0.5 to 1.5 mm²) solid/stranded or 2× (0.75 to 2.5 mm²) finely stranded with ferrule; AWG equivalents are 2× (18 to 12) and 2× (20 to 16). Auxiliary contact terminals also screw-type, accepting 2× (20 to 16) or 2× (18 to 14) AWG. Tightening torque for main contacts: 0.8 to 1.2 N·m.

Relative humidity during operation 10 to 95 %. Shock resistance 25 g / 11 ms per IEC 60068-2-27. Substance prohibitance date 05/01/2012 — RoHS-compliant as of that date.

Frequently asked questions

What is the rated current and trip class of 3RV6011-0GA15?

Rated operational current is 0.63 A at AC-3, with a Class 10 thermal overload release.

MPN