Skip to main content
Siemens 3RV6011-0HA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV6011-0HA15 SIRIUS Motor Protection Breaker, 0.8 A

MPN3RV6011-0HA15

Siemens SIRIUS motor protection circuit breaker, 3RV6011-0HA15, 0.8 A, Class 10, 3-pole, size S00, screw terminals, 690 V, 50/60 Hz.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV6011-0HA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV6011-0HA15 — Electrical
ParameterValue
Rated operational current (Ie)0.8 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV6011-0HA15 — Protection & Tripping
ParameterValue
Overload release setting range0.55 ... 0.8 A
Instantaneous short-circuit trip current10 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
3RV6011-0HA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 to 12), 2x (20 to 16)
3RV6011-0HA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV6011-0HA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV6011-0HA15 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

It is a 3-pole device in the compact S00 frame size, rated for 690 V at AC-3 duty and 50/60 Hz. Power loss is 6 W typical. This is a current-production part (lifecycle stage: current).

The 0.8 A rated current and Class 10 trip curve mean this breaker is sized for a small motor — fractional horsepower, say a 0.25 kW three-phase motor at 400 V. The 690 V AC-3 rating covers switching motor loads at line voltage up to that level. The S00 frame (45 mm wide, 96 mm deep, 97 mm high) fits the standard DIN-rail footprint; clearance requirements are 50 mm above and below, 30 mm to the sides, and zero forward/backward clearance needed.

Integration — DIN rail and wiring

Accepts 2× (0.5 to 1.5 mm²) or 2× (0.75 to 2.5 mm²) solid or stranded wire on main contacts; AWG equivalents 2× (18 to 12) or 2× (20 to 16). Auxiliary contacts use screw terminals, 2× (0.5 to 1.5 mm²) or 2× (0.75 to 2.5 mm²). Terminal torque for main contacts: 0.8 to 1.2 N·m. The transverse auxiliary switch design allows side-by-side ganging without extra spacing beyond the 30 mm side clearance.

Frequently asked questions

How do I get pricing and availability for 3RV6011-0HA15?

The part is sourced and quoted to order against an RFQ through independent distribution. Current pricing and availability are confirmed at quote time — submit an RFQ for a firm quote.

What is the closest functional second-source for 3RV6011-0HA15?

The closest functional peer is the 3RV6011-0CA10, which shares the same S00 frame, 3-pole design, screw terminals, and Class 10 trip. The key difference is the rated current — 3RV6011-0HA15 is 0.8 A, while 3RV6011-0CA10 is rated at a different current level. Verify the motor FLA before substituting.

Will 3RV6011-0HA15 drop into a panel specified for 3RV6011-0CA10?

Yes — both are S00 frame size, same DIN-rail footprint, same screw-terminal layout, same 3-pole configuration. No rewiring or panel modification is needed for the physical fit. Only the current rating differs; confirm the 0.8 A setting matches the motor protection requirement.

What compliance documentation does Siemens provide for 3RV6011-0HA15?

The part carries a substance prohibition date of 05/01/2012, indicating RoHS compliance. As a SIRIUS motor protection breaker, it is designed to meet IEC/EN 60947-4-1 and related standards. Specific UL, CSA, or REACH documentation should be confirmed at quote time.

MPN