Siemens 3RV6011-0JA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV6011-0JA15 SIRIUS Motor Protection Circuit Breake

MPN3RV6011-0JA15

Siemens SIRIUS motor protection circuit breaker, 3RV6011-0JA15, 1 A rated operational current, Class 10 trip, 690 V AC-3, 50/60 Hz, size S00, screw-type terminals, for 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV6011-0JA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV6011-0JA15 — Electrical
ParameterValue
Rated operational current (Ie)1 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV6011-0JA15 — Protection & Tripping
ParameterValue
Overload release setting range0.7 ... 1 A
Instantaneous short-circuit trip current13 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
3RV6011-0JA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 to 12), 2x (20 to 16)
3RV6011-0JA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV6011-0JA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV6011-0JA15 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Motor protection circuit breaker, 1 A, Class 10 — panel fit and trip curve

The magnetic short-circuit trip handles fault clearing independently of the thermal element. The S00 frame is compact: 45 mm wide, 97 mm tall, 96 mm deep. That 50 mm vertical gap is non-negotiable for arc-fault venting — don't crowd the enclosure top.

Main and auxiliary/control circuits use screw-type terminals. Main contacts accept 2× (0.5 to 1.5 mm²) solid/stranded or 2× (0.75 to 2.5 mm²), or AWG 2× (18 to 12) and 2× (20 to 16). Auxiliary contacts accept 2× (0.5 to 1.5 mm²) or 2× (0.75 to 2.5 mm²), AWG 2× (20 to 16) and 2× (18 to 14). Torque for main contact screws: 0.8 to 1.2 N·m. Finely stranded wire requires ferrule processing.

Frequently asked questions

What is the 3RV6011-0JA15 used for?

It is a motor protection circuit breaker for thermal-magnetic overload and short-circuit protection of motors up to 1 A, Class 10 trip, size S00, for 35 mm DIN rail mounting.

What are the key ratings of the 3RV6011-0JA15?

Rated operational current 1 A, AC-3 rated voltage 690 V, operating frequency 50/60 Hz, trip class 10, power loss 6 W typical.

Where can I buy the 3RV6011-0JA15?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3RV6011-0JA15