Skip to main content
Siemens 3RV6011-0KA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV6011-0KA10 SIRIUS Motor Protection CB, 1.25 A, Cl

MPN3RV6011-0KA10

Siemens SIRIUS motor protection circuit breaker, 3RV6011-0KA10, 3-pole, 1.25 A rated operational current, Class 10 thermal-magnetic trip, 690 V AC-3, screw terminals, size S00, for 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV6011-0KA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV6011-0KA10 — Electrical
ParameterValue
Rated operational current (Ie)1.25 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV6011-0KA10 — Protection & Tripping
ParameterValue
Overload release setting range0.9 ... 1.25 A
Instantaneous short-circuit trip current16 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
3RV6011-0KA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 to 12), 2x (20 to 16)
3RV6011-0KA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV6011-0KA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV6011-0KA10 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

Its 1.25 A rated operational current (AC-3 at 400 V) and thermal-magnetic overload release (Class 10) mean it protects small motors — fractional-horsepower pumps, fans, or conveyors — from sustained overload and short-circuit faults. The magnetic short-circuit trip clears hard faults fast, while the thermal element allows a brief inrush before tripping, matching motor start curves.

Snap-on mounting onto 35 mm DIN rail per DIN EN 60715, with screw terminals for the main circuit (2x 0.75–2.5 mm² solid/stranded, or 2x 4 mm²).

Frequently asked questions

Where can I buy the 3RV6011-0KA10?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 3RV6011-0KA10 drop into a panel specified for 3RV6011-0CA10 without rewiring?

Both are SIRIUS size S00 breakers with the same 45 mm width, 96 mm depth, and screw-terminal arrangement. The 3RV6011-0KA10 is a 1.25 A Class 10 unit; the 3RV6011-0CA10 carries a different current rating. Panel fit is identical, but verify the current setting matches the motor full-load amps before swapping.

What compliance documentation does Siemens provide for 3RV6011-0KA10?

The part carries a substance prohibitance date of 05/01/2012, indicating RoHS compliance. Standard Siemens documentation includes the declaration of conformity and environmental compliance sheets.

MPN
3RV6011-0KA10