Siemens 3RV6011-1AA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV6011-1AA15 SIRIUS Motor Protection Circuit Breake

MPN3RV6011-1AA15

Siemens SIRIUS 3RV6011-1AA15, motor protection circuit breaker, Size S00, 3-pole, 1.6 A rated operational current, Trip Class 10, screw terminals, 690 V, 50-60 Hz.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV6011-1AA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV6011-1AA15 — Electrical
ParameterValue
Rated operational current (Ie)1.6 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV6011-1AA15 — Protection & Tripping
ParameterValue
Overload release setting range1.1 ... 1.6 A
Instantaneous short-circuit trip current21 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
3RV6011-1AA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV6011-1AA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV6011-1AA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV6011-1AA15 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens 3RV6011-1AA15 is a SIRIUS motor-protection circuit breaker in the S00 frame size, rated 1.6 A operational current at 690 V AC-3, 50-60 Hz. Trip Class 10 thermal overload release paired with a magnetic short-circuit trip — covers the two protection curves a motor branch needs: overload (thermal) and short-circuit (magnetic). The 1.6 A rating sets the full-load current it carries continuously; the magnetic trip clears faults fast enough to protect the downstream contactor and cable.

Snap-on mounting onto 35 mm DIN rail per DIN EN 60715, screw-fastened as well. 45 mm wide, 97 mm tall, 96 mm deep — fits a standard S00 footprint. Mounting position any, so vertical or horizontal panel layouts work. Clearance: 50 mm above and below, 30 mm at the sides, zero forward or backward — lets you pack rows tight if the heat rise stays within the -20 to +60 °C operating range. Accepts 2×(0.5…1.5 mm²) or 2×(0.75…2.5 mm²) solid or stranded, AWG 18–12 for main contacts. Torque 0.8–1.2 N·m. Typical power loss 6 W total — negligible in a ventilated enclosure but factor into a sealed panel's thermal budget.

Frequently asked questions

What is the closest functional second-source for 3RV6011-1AA15?

The 3RV6011-0CA10 is a close functional peer in the same S00 frame and Class 10, but verify the rated current — the 3RV6011-1AA15 is set at 1.6 A, while the 0CA10 covers a different current range. Both share the same DIN rail footprint, screw terminals, and thermal-magnetic release design, so a panel laid out for one can accept the other without rewiring, provided the current setting matches the motor FLA.