Siemens 3RV6011-1BA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV6011-1BA10 SIRIUS Motor Protection Circuit Breake

MPN3RV6011-1BA10

Siemens SIRIUS, motor protection circuit breaker, 3RV6011-1BA10, size S00, 2 A rated current, Class 10 thermal-magnetic overload, screw terminals, 45 mm width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV6011-1BA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV6011-1BA10 — Electrical
ParameterValue
Rated operational current (Ie)2 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV6011-1BA10 — Protection & Tripping
ParameterValue
Overload release setting range1.4 ... 2 A
Instantaneous short-circuit trip current26 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
3RV6011-1BA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 to 12), 2x (20 to 16)
3RV6011-1BA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV6011-1BA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV6011-1BA10 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

DIN rail fit and panel space

Clearance: 50 mm above and below, zero sideways — so you can butt it against other S00 devices without extra spacing. Terminal capacity accepts 2x 0.75–2.5 mm² solid or stranded, or 2x 4 mm², with tightening torque 0.8–1.2 N·m.

Class 10 trip means it will disconnect before the motor windings overheat under locked-rotor conditions, within 10 seconds at 7.2x set current. The magnetic short-circuit release handles faults above that threshold. Rated impulse withstand voltage 6 kV, surge voltage resistance rated at that level, so it coordinates with standard distribution panel surge ratings. Power loss about 6 W total typical — negligible for enclosure heat calc but worth noting in a sealed cabinet.

Frequently asked questions

Will 3RV6011-1BA10 drop into a panel built for 3RV6011-0CA10?

Both are S00 frame size with the same 45 mm width and DIN rail mounting, so the mechanical fit is identical. The difference is the rated current — 2 A on this unit versus the 0CA10's rating — so verify your motor FLA matches before swapping.