Skip to main content
Siemens 3RV6011-1CA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV6011-1CA15 SIRIUS Motor Protection Circuit Breake

MPN3RV6011-1CA15

Siemens SIRIUS, motor protection circuit breaker, 3RV6011-1CA15, 2.5 A rated operational current, Class 10 trip, 690 V AC-3, 3-pole, screw terminals, frame size S00.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV6011-1CA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV6011-1CA15 — Electrical
ParameterValue
Rated operational current (Ie)2.5 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV6011-1CA15 — Protection & Tripping
ParameterValue
Overload release setting range1.8 ... 2.5 A
Instantaneous short-circuit trip current33 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
3RV6011-1CA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 to 12), 2x (20 to 16)
3RV6011-1CA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV6011-1CA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV6011-1CA15 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The 45 mm width and 96 mm depth fit standard S00 panel layouts. Screw-type terminals on both main and auxiliary circuits accept 2x (0.5 to 1.5 mm²) solid or stranded, or 2x (0.75 to 2.5 mm²). AWG equivalents: 2x (18 to 12) for main contacts, 2x (20 to 16) for auxiliary. Torque to 0.8 to 1.2 N·m.

Rating context and so-what

Rated 2.5 A at AC-3 for switching motor loads — that is the current the breaker will carry continuously and trip on overload, not the short-circuit rating. Maximum switching frequency at AC-3 is 15 operations per hour. Thermal overload release protects against sustained overcurrent; magnetic short-circuit trip handles fault clearing. Surge voltage resistance rated at 6 kV, shock tested to 25 g / 11 ms per IEC 60068-2-27. Ambient operating range -20 to +60 °C, storage -50 to +80 °C, with 10 to 95 % relative humidity.

Frequently asked questions

What is 3RV6011-1CA15's depth and width?

Depth is 96 mm, width is 45 mm, height is 97 mm. These dimensions match the S00 frame size.

Will 3RV6011-1CA15 drop into a panel specified around 3RV6011-0CA10?

Both are S00 frame size motor protection breakers with the same mounting footprint (snap-on 35 mm DIN rail) and terminal layout. The 3RV6011-1CA15 should physically fit without rewiring, but verify the current rating difference — the -1CA15 is 2.5 A, while the -0CA10 is a different rating. Check your BOM for the correct trip current.

How do I get current pricing and availability for 3RV6011-1CA15?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through our independent distribution channels.

What compliance documentation does this part carry?

RoHS compliance is indicated by the substance prohibition date of 05/01/2012. The part is designed to IEC standards for motor protection circuit breakers.

MPN
3RV6011-1CA15