Skip to main content
Siemens 3RV6011-1EA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV6011-1EA15 SIRIUS Motor Protection Circuit Breake

MPN3RV6011-1EA15

Siemens SIRIUS 3RV6011-1EA15 motor protection circuit breaker, size S00, 4 A rated operational current, Class 10 thermal-magnetic overload and magnetic short-circuit release, 690 V AC-3, 50/60 Hz, screw terminals, snap-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV6011-1EA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV6011-1EA15 — Electrical
ParameterValue
Rated operational current (Ie)4 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV6011-1EA15 — Protection & Tripping
ParameterValue
Overload release setting range2.8 ... 4 A
Instantaneous short-circuit trip current52 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
3RV6011-1EA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV6011-1EA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV6011-1EA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV6011-1EA15 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

It combines a thermal overload relay (Class 10 trip characteristic) with a magnetic short-circuit release in a single 3-pole device. The 4 A rated operational current at AC-3 duty means it directly protects a motor drawing that full-load current, with the thermal element tracking the heating curve of the motor windings. Rated at 690 V AC-3 maximum and 50/60 Hz, it covers standard three-phase motor loads across most industrial voltages. The magnetic short-circuit release clears faults fast enough to coordinate with downstream contactors and upstream breakers in a selectivity study.

The 45 mm width (three modular units) and 96 mm depth fit standard motor control center buckets and small enclosures. Terminals accept 2x (0.5 to 1.5 mm²) solid or stranded, or 2x (0.75 to 2.5 mm²) — AWG equivalents 2x (18 to 12) for main contacts, 2x (20 to 16) for auxiliary. Screw torque 0.8 to 1.2 N·m on the main terminals.

Ambient conditions and durability

Withstands 25 g shock at 11 ms per IEC 60068-2-27. Relative humidity 10 to 95 % during operation — suitable for unconditioned plant-floor environments.

Frequently asked questions

What is the 3RV6011-1EA15 rated current and trip class?

Rated operational current is 4 A at AC-3, with a Class 10 thermal overload trip characteristic.

Will the 3RV6011-1EA15 drop into a panel wired for the 3RV6011-0CA10?

Both are size S00, same 45 mm width and DIN-rail mount, so mechanical fit is identical. However, the 0CA10 has a different current rating and trip setting — verify the motor FLA matches the 4 A rating of the 1EA15 before swapping.

MPN
3RV6011-1EA15