Skip to main content
Siemens 3RV6011-1HA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV6011-1HA15 SIRIUS Motor Protection CB, 8 A, Class

MPN3RV6011-1HA15

Siemens SIRIUS motor protection circuit breaker, 3RV6011-1HA15, Size S00, 3-pole, 8 A rated, Class 10 trip class, screw terminals, 50/60 Hz.

$212.29Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV6011-1HA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV6011-1HA15 — Electrical
ParameterValue
Rated operational current (Ie)8 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV6011-1HA15 — Protection & Tripping
ParameterValue
Overload release setting range5.5 ... 8 A
Instantaneous short-circuit trip current104 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
3RV6011-1HA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 to 12), 2x (20 to 16)
3RV6011-1HA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV6011-1HA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV6011-1HA15 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens 3RV6011-1HA15 is a SIRIUS motor protection circuit breaker — Size S00, 3-pole, rated 8 A with a Class 10 trip curve, meaning it clears overloads fast enough to protect standard induction motors during start-up without nuisance tripping. Rated operational current is 8 A at up to 690 V AC-3, switching frequency max 15 operations per hour, so it's sized for a typical small motor branch circuit — think conveyors, pumps, or fans in a control panel.

Mounts in any position on 35 mm DIN rail (screw or snap-on) per DIN EN 60715, with 45 mm width and 96 mm depth — fits standard S00 footprint in a motor control center or panel. Screw-type terminals on both main and auxiliary circuits accept 2x (0.5 to 2.5 mm²) solid/stranded or 2x (18 to 12 AWG) for the mains, with a tightening torque of 0.8 to 1.2 N·m.

Rated for operation from -20 to +60 °C, 10 to 95% relative humidity, with a 6 kV surge voltage withstand — suitable for industrial control panels in unconditioned plant environments. Shock-resistant to 25 g / 11 ms per IEC 60068-2-27; RoHS compliance dated 05/01/2012.

Frequently asked questions

What is the depth of 3RV6011-1HA15?

The depth is 96 mm, with a width of 45 mm and height of 97 mm — standard S00 frame size.

MPN