Siemens 3RV6011-1KA15 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV6011-1KA15 SIRIUS Motor Protection Circuit Breake

MPN3RV6011-1KA15

Siemens SIRIUS motor protection circuit breaker, 3RV6011-1KA15, S00 frame, 12.5 A rated operational current, CLASS 10, 690 V AC-3, 45 mm wide, screw and snap-on DIN rail mounting.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV6011-1KA15 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV6011-1KA15 — Electrical
ParameterValue
Rated operational current (Ie)12.5 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3

Protection & Tripping

3RV6011-1KA15 — Protection & Tripping
ParameterValue
Overload release setting range9 ... 12.5 A
Instantaneous short-circuit trip current163 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes

Connections

3RV6011-1KA15 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 to 12), 2x (20 to 16)

Mechanical

3RV6011-1KA15 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV6011-1KA15 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV6011-1KA15 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

The Siemens 3RV6011-1KA15 is a SIRIUS motor protection circuit breaker in the S00 frame, rated 12.5 A operational current with a CLASS 10 trip characteristic. It provides thermal overload and magnetic short-circuit protection in a single device, sized for the compact 45 mm width that fits standard 35 mm DIN rail per DIN EN 60715 — no extra panel cutout needed. Rated for 690 V at AC-3 duty and 50/60 Hz, this breaker handles motor starting currents up to that voltage class. The thermal overload release follows a CLASS 10 curve, meaning it trips within 10 seconds at 7.2× the current setting — tight enough to protect standard induction motors during a stalled-rotor condition without nuisance tripping on a normal start. Mounting position is unrestricted, and the screw-type terminals accept 2×(0.5…1.5 mm²) solid or 2×(0.75…2.5 mm²) stranded — common panel wire sizes. The 7 W typical power loss at full load is manageable inside a sealed enclosure, but group multiple units and check the internal temperature rise against the -20 to +60 °C operating range.

S00 frame and panel fit

The 3RV6011-1KA15 measures 96 mm deep, 45 mm wide, and 97 mm tall. The S00 frame is the smallest in the SIRIUS breaker family, so it leaves room for auxiliary contact blocks or a separate 24 VDC control transformer on the same DIN rail. Clearance requirements: 50 mm above and below, 30 mm to the side, and zero forward or backward — tight against the backpanel. Snap-on mounting onto 35 mm DIN rail per DIN EN 60715 is standard; screw fixing is also supported for vibration-prone installations. The any-position mounting means you can orient it vertically or horizontally inside the gland plate area without derating the trip curve.

Lifecycle and compliance

Shock resistance is rated at 25 g for 11 ms per IEC 60068-2-27, and surge voltage withstand is 6 kV — figures that support installation in industrial panels subject to mechanical stress and switching transients.

The transverse auxiliary switch design and screw-type terminals for the auxiliary/control circuit match the standard SIRIUS accessory range. If you need to add a remote trip indication or a shunt trip, the same auxiliary blocks that fit the 3RV2 series also fit this S00 frame. Maximum switching frequency at AC-3 is 15 cycles per hour — enough for a pump or fan start once every four minutes, but not for high-cycling applications like a stamping press or rapid-index conveyor. For those, step up to a larger frame or a contactor with a higher rated operating frequency.

Frequently asked questions

What are the key ratings for the 3RV6011-1KA15?

Rated operational current is 12.5 A at AC-3 duty, rated voltage is 690 V, trip class is CLASS 10, and the frame size is S00. It operates at 50/60 Hz and has a typical power loss of 7 W.

Will the 3RV6011-1KA15 drop into a panel specified for a 3RV6011-0CA10?

Both are S00-frame breakers on the same 45 mm DIN-rail footprint, so the mechanical fit is identical. Verify the current rating and trip class on your BOM — the 0CA10 is a different rating variant, not a direct electrical substitute without checking the motor FLA.

How do I get current pricing and availability for the 3RV6011-1KA15?

Submit an RFQ against this order code. Pricing and confirmed availability are quoted at quote time through independent distribution channels; no stock figures or price lists are published here.

What compliance documentation does Siemens provide for the 3RV6011-1KA15?

RoHS compliance is confirmed with a substance prohibition date of 05/01/2012. The part carries shock resistance ratings per IEC 60068-2-27 and surge voltage withstand per IEC standards. Check the manufacturer's declaration for REACH and UKCA if those are required for your market.

MPN
3RV6011-1KA15