Skip to main content
Siemens 3RV6011-4AA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV6011-4AA10 SIRIUS Motor Protection Circuit Breake

MPN3RV6011-4AA10

Siemens SIRIUS 3RV6011-4AA10, Size S00 motor protection circuit breaker, 3-pole, 16 A rated operational current, Class 10 trip, screw terminals, 45 mm width, 96 mm depth.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV6011-4AA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV6011-4AA10 — Electrical
ParameterValue
Rated operational current (Ie)16 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3

Protection & Tripping

3RV6011-4AA10 — Protection & Tripping
ParameterValue
Overload release setting range10 ... 16 A
Instantaneous short-circuit trip current208 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes

Connections

3RV6011-4AA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 to 12), 2x (20 to 16)

Mechanical

3RV6011-4AA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV6011-4AA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV6011-4AA10 — Specifications
ParameterValue
Design Of The Productfor motor protection

Product details

What it is and what it does

The Siemens 3RV6011-4AA10 is a SIRIUS Size S00 motor protection circuit breaker, 3-pole, rated 16 A operational current with a thermal-magnetic trip — thermal overload release for Class 10 protection, magnetic short-circuit release for fault clearing. It's the dedicated overcurrent and short-circuit protector for a 3-phase motor branch circuit, sized for the S00 frame's compact DIN-rail footprint. Rated insulation voltage 690 V, AC-3 switching at 400 V carries the full 16 A — that's the motor-rated current for a standard 3-phase induction motor up to roughly 7.5 kW at 400 V. The Class 10 trip curve means it disconnects within 10 seconds at 7.2× the thermal setting, matching the typical heating curve of a standard squirrel-cage rotor during a stall.

Panel fit and mounting

45 mm wide, 97 mm tall, 96 mm deep — snaps onto 35 mm DIN rail per DIN EN 60715, or screws direct to a backplate. Mounting position any; clearance: 50 mm above and below, 30 mm at the sides, zero forward or backward. Screw-type terminals on top and bottom accept 2×(0.75–2.5 mm²) solid/stranded or 2×4 mm² solid; AWG 2×(18–12) solid, 2×(20–16) stranded. Torque to 0.8–1.2 N·m. The S00 frame keeps the wiring gutters clear — no need to oversize the enclosure for this breaker.

Compliance and documentation

RoHS compliant with substance prohibition date 05/01/2012. The SIRIUS series carries IEC/EN 60947-2 and 60947-4-1 certifications for motor protection and circuit-breaking duty. Shock resistance 25 g / 11 ms per IEC 60068-2-27; operating temperature -20 to +60 °C, storage -50 to +80 °C. Relative humidity 10–95 % during operation.

Frequently asked questions

Will 3RV6011-4AA10 drop into a panel specified around 3RV6011-0CA10 without rewiring?

Both are Size S00, 3-pole, same 45 mm width and DIN-rail mounting. The 3RV6011-4AA10 is rated 16 A; the 3RV6011-0CA10 is a lower-current variant. If the existing panel wiring and upstream protection are sized for 16 A, the swap is a direct mechanical fit — same footprint, same terminal layout.

What is 3RV6011-4AA10's width and depth for panel layout?

Width 45 mm, depth 96 mm, height 97 mm. Clearance: 50 mm above and below, 30 mm at sides, zero forward or backward. Snaps onto 35 mm DIN rail.

MPN
3RV6011-4AA10