Siemens 3RV6311-1KC10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV6311-1KC10 SIRIUS Circuit Breaker, 12.5 A, 690 V

MPN3RV6311-1KC10

Siemens SIRIUS circuit breaker, 3RV6311-1KC10, size S00, 12.5 A rated operational current at AC-3 400 V, 690 V insulation voltage, 50/60 Hz, screw terminals, for starter combinations.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV6311-1KC10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV6311-1KC10 — Electrical
ParameterValue
Rated operational current (Ie)12.5 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV6311-1KC10 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current163 A
Short-circuit trip typemagnetic
Short-circuit protectionYes
3RV6311-1KC10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 to 12), 2x (20 to 16)
3RV6311-1KC10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV6311-1KC10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV6311-1KC10 — Specifications
ParameterValue
Design Of The Productfor starter combinations

Product details

What this breaker does in a motor branch

Rated 12.5 A at AC-3 duty (400 V), it handles the locked-rotor inrush of a motor up to that current class, then trips magnetically at 163 A for a hard fault. The 690 V rated insulation voltage with pollution degree 3 gives it headroom on 400 V line-to-line systems common in European and Asian panels.

Width 45 mm, depth 96 mm, height 97 mm. Screw terminals accept 2x (0.75 to 2.5 mm²) solid/stranded. Torque 0.8–1.2 N·m. Operating -20 to +60 °C.

Substance prohibition (RoHS) compliance date 05/01/2012. Shock resistance 25g / 11 ms per IEC 60068-2-27. Surge voltage resistance 6 kV. Relative humidity 10–95 % during operation. The SIRIUS series carries UL, CSA, CE, and IEC certifications standard for the brand — documentation available on request.

Frequently asked questions

Will 3RV6311-1KC10 drop into a panel specified around 3RV6011-0CA10?

Both are S00 frame size on 45 mm width and share the same DIN rail mounting pattern. Terminal layout and clearance requirements are identical — no rewiring needed for the footprint. The key difference is the trip curve and current rating; verify the 12.5 A setting matches your motor FLA before swapping.