Skip to main content
Siemens 3RV6321-4DC10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV6321-4DC10 SIRIUS Circuit Breaker, 25 A, 690 V

MPN3RV6321-4DC10

Siemens SIRIUS circuit breaker, for starter combinations, 3RV6321-4DC10, 25 A AC-3 at 400 V, 690 V rated, size S0, screw-type terminals, snap-on DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV6321-4DC10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS0
3RV6321-4DC10 — Electrical
ParameterValue
Rated operational current (Ie)25 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV6321-4DC10 — Protection & Tripping
ParameterValue
Instantaneous short-circuit trip current325 A
Short-circuit trip typemagnetic
Short-circuit protectionYes
3RV6321-4DC10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
Conductor range, AWG (main contacts)2x (16 ... 12), 2x (14 ... 8)
3RV6321-4DC10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV6321-4DC10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV6321-4DC10 — Specifications
ParameterValue
Design Of The Productfor starter combinations

Product details

Rated 25 A operational current at AC-3 (400 V), it handles motor switching duty up to that current; the instantaneous magnetic short-circuit trip responds at 325 A, clearing faults fast enough to protect downstream contactors and cables. Insulation rated at 690 V with surge withstand of 6 kV, so it's comfortable on 400 V line-to-line systems with decent headroom.

Size S0 frame, 45 mm wide, 97 mm tall, 96 mm deep. Any mounting position allowed. Screw-type terminals on main circuit accept 2x (1…2.5 mm²) solid/stranded or 2x (2.5…10 mm²), torque 2…2.5 N·m.

Frequently asked questions

What is 3RV6321-4DC10's listed depth?

96 mm depth, 45 mm width, 97 mm height — size S0 frame.

Will 3RV6321-4DC10 drop into a panel that was specified around 3RV6021-4DA10 without rewiring?

Both are S0 frame, same DIN rail footprint, same screw-type terminal arrangement. Panel cutout and clearance requirements match — no rewiring needed for the mechanical swap, but verify the trip setting difference (instantaneous trip at 325 A on this unit) against your motor FLA.

MPN
3RV6321-4DC10