Siemens 3RV6411-0DA10 — Motor Protection Circuit Breakers (MPCB)

Siemens SIRIUS 3RV6411-0DA10 Circuit Breaker, 0.32 A, CLASS

MPN3RV6411-0DA10

Siemens SIRIUS circuit breaker, 3RV6411-0DA10, for transformer protection, 3-pole, 0.32 A, CLASS 10, 690 V, screw terminals, S00 size, snap-on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV6411-0DA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV6411-0DA10 — Electrical
ParameterValue
Rated operational current (Ie)0.32 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV6411-0DA10 — Protection & Tripping
ParameterValue
Overload release setting range0.22 ... 0.32 A
Instantaneous short-circuit trip current6.5 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
3RV6411-0DA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 to 12), 2x (20 to 16)
3RV6411-0DA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV6411-0DA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV6411-0DA10 — Specifications
ParameterValue
Design Of The Productfor transformer protection

Product details

What this SIRIUS breaker does

Rated operational current is 0.32 A at AC-3 duty (400 V), with a maximum rated voltage of 690 V. This means it protects the transformer primary against sustained overloads and short circuits, tripping fast enough (CLASS 10) to prevent winding damage while ignoring harmless inrush.

The S00 frame size keeps the footprint compact: 45 mm wide, 97 mm tall, 96 mm deep. That 45 mm width is the same as a standard single-pole MCB footprint, so it slots into a crowded DIN rail without re-spacing.

Frequently asked questions

Will 3RV6411-0DA10 drop into a panel specified around 3RV6021-4DA10 without rewiring?

Both are S00 frame size and mount on 35 mm DIN rail, so the mechanical fit is the same. However, the 3RV6411-0DA10 is rated 0.32 A for transformer protection, while the 3RV6021-4DA10 is a motor-protective breaker with a different trip curve. Check the load current and protection requirements before swapping — the terminals are screw-type on both.

MPN
3RV6411-0DA10