Specifications

3RV6411-0GA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV6411-0GA10 — Electrical
ParameterValue
Rated operational current (Ie)0.63 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV6411-0GA10 — Protection & Tripping
ParameterValue
Overload release setting range0.45 ... 0.63 A
Instantaneous short-circuit trip current13 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
3RV6411-0GA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 to 12), 2x (20 to 16)
3RV6411-0GA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany
3RV6411-0GA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV6411-0GA10 — Specifications
ParameterValue
Design Of The Productfor transformer protection

Product details

Three poles, Size S00 frame, screw-type terminals top and bottom.

The S00 frame takes 45 mm width and 96 mm depth — fits standard 45 mm module spacing in a panel. Mounting position any orientation; clearance needs 50 mm above and below, 30 mm to the side for heat dissipation. Ambient during operation -20 to +60 °C, so it's fine inside a closed panel with other heat sources.

Rated operational voltage 690 V, surge voltage resistance 6 kV. Thermal overload release paired with magnetic short-circuit trip. Power loss 5 W typical at rated current.

Frequently asked questions

What is the closest functional second-source to 3RV6411-0GA10?

The 3RV6011-0CA10 is the motor-protection variant in the same S00 frame — same footprint, same DIN rail mount, but its overload curve and magnetic trip are calibrated for motor starting, not transformer inrush. For transformer duty, stick with the 3RV6411-0GA10.

MPN
3RV6411-0GA10