Siemens 3RV6411-0KA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV6411-0KA10 SIRIUS Circuit Breaker, 1.25 A, Class

MPN3RV6411-0KA10

Siemens SIRIUS circuit breaker, 3RV6411-0KA10, for transformer protection, 1.25 A rated operational current, Class 10, 3-pole, 690 V AC-3, screw-type terminals, size S00, snap-on 35 mm DIN rail.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV6411-0KA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV6411-0KA10 — Electrical
ParameterValue
Rated operational current (Ie)1.25 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3

Protection & Tripping

3RV6411-0KA10 — Protection & Tripping
ParameterValue
Overload release setting range0.9 ... 1.25 A
Instantaneous short-circuit trip current26 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes

Connections

3RV6411-0KA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV6411-0KA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV6411-0KA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV6411-0KA10 — Specifications
ParameterValue
Design Of The Productfor transformer protection

Product details

Transformer-protection circuit breaker, 1.25 A, Class 10 — SIRIUS 3RV6411-0KA10

The Siemens 3RV6411-0KA10 is a SIRIUS circuit breaker designed specifically for transformer protection, with a rated operational current of 1.25 A at 400 V AC-3 duty and a thermal-magnetic release (Class 10 overload, magnetic short-circuit trip). Rated for 690 V AC-3 maximum, 50/60 Hz, and 3-pole switching, it handles the inrush characteristic of small transformers without nuisance tripping — the Class 10 curve allows a brief overload window before the thermal element opens. Mounts on 35 mm DIN rail per DIN EN 60715 via screw and snap-on fastening, in any orientation, with 50 mm clearance above and below and 30 mm at the sides for heat dissipation and wiring access.

Sizing and coordination for transformer primary protection

At 1.25 A and Class 10, this breaker is sized for the primary side of control transformers or small power transformers where the inrush peak can exceed the full-load current for a few seconds. The magnetic short-circuit trip clears a hard fault fast, while the thermal element rides through the magnetizing inrush. The 6 W total power loss at rated current is low enough that multiple units can be ganged on a DIN rail without forced cooling, provided the 30 mm side clearance is respected. Compared to the general-purpose 3RV6011-0CA10 (same frame size S00, same 1.25 A rating but Class 10A), the 3RV6411-0KA10's Class 10 curve is slightly slower on overload — a deliberate choice for transformer primary duty where the load is a magnetic circuit, not a motor.

Lifecycle and compliance — active, RoHS-compliant

RoHS compliance date is 05/01/2012, confirming the part meets the EU RoHS substance restrictions effective from that date. REACH and WEEE compliance are standard for the SIRIUS series.

Panel integration — DIN rail, screw terminals, clearances

Snap-on mounting onto 35 mm DIN rail (DIN EN 60715) with screw fastening for vibration resistance. The 45 mm width (3-module) fits standard enclosure cutouts. Screw-type terminals on top and bottom accept 2x (0.75–2.5 mm²) solid/stranded or 2x 4 mm², or AWG 18–12 / 20–16. Tightening torque: 0.8–1.2 N·m. Depth 96 mm, height 97 mm — fits standard 100 mm deep enclosures. Clearances: 50 mm above/below, 30 mm sides, 0 mm forward/backward (no extra space needed beyond the device envelope). Operating temperature -20 to +60 °C, storage -50 to +80 °C, relative humidity 10–95%. Shock rated 25g / 11 ms per IEC 60068-2-27. Installation altitude up to 2000 m.

Frequently asked questions

What is the closest functional second-source for 3RV6411-0KA10?

The 3RV6011-0CA10 is the closest peer in the same S00 frame size and 1.25 A rating, but it uses a Class 10A trip curve (faster on overload) versus the Class 10 curve on the 3RV6411-0KA10. For transformer primary protection, the 3RV6411-0KA10's slower curve is the correct choice; the 3RV6011-0CA10 may nuisance-trip on transformer inrush.

Will 3RV6411-0KA10 drop into a panel specified around 3RV6011-0CA10 without rewiring?

Yes — both are size S00, same 45 mm width, same DIN rail mounting, same screw terminal arrangement. The swap is mechanical and electrical drop-in; only the trip curve differs.