Siemens 3RV6411-1GA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV6411-1GA10 SIRIUS Circuit Breaker, 6.3 A, Class 1

MPN3RV6411-1GA10

Siemens SIRIUS circuit breaker, 3RV6411-1GA10, for transformer protection, 3-pole, size S00, rated current 6.3 A, Trip Class 10, 690 V, screw terminals, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV6411-1GA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV6411-1GA10 — Electrical
ParameterValue
Rated operational current (Ie)6.3 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV6411-1GA10 — Protection & Tripping
ParameterValue
Overload release setting range4.5 ... 6.3 A
Instantaneous short-circuit trip current130 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
3RV6411-1GA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV6411-1GA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV6411-1GA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV6411-1GA10 — Specifications
ParameterValue
Design Of The Productfor transformer protection

Product details

Transformer-protection circuit breaker, 6.3 A, Class 10

The magnetic short-circuit trip handles fault clearing, and the breaker is rated for 690 V AC at AC-3 duty.

Any mounting position is allowed. Clearance: 50 mm upwards and downwards, 30 mm at the side, zero forwards or backwards. Panel builders can plan for the 45 mm width and 96 mm depth footprint.

Rated operational current of 6.3 A at AC-3 (400 V) means this breaker is sized for the inrush and running current of a transformer up to that load. The 690 V rated value covers most 400/480 V systems with headroom.

Relative humidity 10 to 95 %. Installation altitude up to 2000 m. Shock resistance 25 g / 11 ms per IEC 60068-2-27. RoHS compliance date 05/01/2012 (substance prohibitance).

Frequently asked questions

What is the closest functional second-source for 3RV6411-1GA10?

The 3RV6011-0CA10 is a peer in the same SIRIUS family but has different ratings; verify fit against your BOM line before substituting.

What are the key ratings of 3RV6411-1GA10?

Rated operational current 6.3 A at AC-3 (400 V), Trip Class 10, rated voltage 690 V, 3-pole, size S00.

Where can I buy 3RV6411-1GA10?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN
3RV6411-1GA10