Skip to main content
Siemens 3RV6411-1HA10 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV6411-1HA10 SIRIUS Circuit Breaker, 8 A, Class 10,

MPN3RV6411-1HA10

Siemens SIRIUS circuit breaker for transformer protection, 3RV6411-1HA10, 8 A rated current, Class 10 trip, 690 V, 3-pole, Size S00, screw terminals, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV6411-1HA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV6411-1HA10 — Electrical
ParameterValue
Rated operational current (Ie)8 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV6411-1HA10 — Protection & Tripping
ParameterValue
Overload release setting range5.5 ... 8 A
Instantaneous short-circuit trip current163 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
3RV6411-1HA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 to 12), 2x (20 to 16)
3RV6411-1HA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV6411-1HA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV6411-1HA10 — Specifications
ParameterValue
Design Of The Productfor transformer protection

Product details

Rated for 690 V at AC-3 and 50/60 Hz, it's a 3-pole unit in the compact Size S00 frame (45 mm wide, 97 mm high, 96 mm deep) that screws or snaps onto 35 mm DIN rail per DIN EN 60715. Power loss is 7 W total typical. Screw-type terminals accept 2x (0.75 to 2.5 mm²) solid or stranded, or 2x 4 mm², with a tightening torque of 0.8 to 1.2 N·m.

Panel Integration

At 45 mm wide, three units fit in a 140 mm DIN section, leaving room for a 4-pole contactor alongside. Screw terminals top and bottom keep the wiring plane clean for panel builders. The Size S00 frame means it shares the same footprint as the SIRIUS 3RV2 contactor range for a coordinated motor starter assembly.

Rated surge voltage resistance is 6 kV, and shock resistance per IEC 60068-2-27 is 25 g for 11 ms. Installation altitude is maximum 2,000 m above sea level.

Frequently asked questions

What is the depth of 3RV6411-1HA10?

The depth is 96 mm, with a width of 45 mm and height of 97 mm.

What compliance documentation does this part carry?

RoHS compliance is documented with a substance prohibitance date of May 1, 2012. The part is designed to IEC standards for shock (IEC 60068-2-27) and surge voltage (6 kV).

Where can I buy 3RV6411-1HA10 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN