Siemens 3RV6421-4AA10 SIRIUS Circuit Breaker, 16 A, Class 10

MPN3RV6421-4AA10

Siemens SIRIUS circuit breaker, 3RV6421-4AA10, size S0, 3-pole, 16 A, Class 10, for transformer protection, screw terminals, 690 V, 50/60 Hz.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV6421-4AA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS0
3RV6421-4AA10 — Electrical
ParameterValue
Rated operational current (Ie)16 A
Rated voltage690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
3RV6421-4AA10 — Protection & Tripping
ParameterValue
Overload release setting range10 ... 16 A
Instantaneous short-circuit trip current286 A
Trip classCLASS 10
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
3RV6421-4AA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
Conductor cross-section, finely stranded with ferrule2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
3RV6421-4AA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth96 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV6421-4AA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV6421-4AA10 — Specifications
ParameterValue
Design Of The Productfor transformer protection

Product details

It carries a 16 A rated operational current and a Class 10 trip characteristic, meaning it allows the inrush of a transformer while still tripping fast enough on a hard fault.

Screw-type terminals on top and bottom accept up to 10 mm² solid or 6 mm² finely stranded with ferrules, or 2x 10 mm² solid. Torque to 2–2.5 N·m. Depth is 96 mm, width 45 mm, height 97 mm — fits standard panel layouts.

Frequently asked questions

Where can I buy 3RV6421-4AA10 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability.

What compliance documentation does 3RV6421-4AA10 have?

RoHS compliance date is 05/01/2012. The breaker is designed for IEC 60947 applications and carries the SIRIUS brand.

Will 3RV6421-4AA10 drop into a panel specified around 3RV6021-4DA10 without rewiring?

Both are S0-size breakers on 35 mm DIN rail with screw terminals, so the mechanical footprint and wiring method are the same. However, the 3RV6421-4AA10 is a transformer-protection variant (Class 10, 16 A), while the 3RV6021-4DA10 is a motor-protective breaker — verify the trip curve and current rating match your load before swapping.

MPN