Siemens 3RW3027-2BB04 — Soft Starters

Siemens 3RW3027-2BB04 SIRIUS Soft Starter, 32 A, 600 V

MPN3RW3027-2BB04
Active

Siemens SIRIUS 3RW3027-2BB04 soft starter, 32 A at 40 °C, 600 V insulation voltage, size S0, integrated bypass contact system, spring-loaded terminals for main and control circuits, screw and snap-on mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW3027-2BB04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW3027-2BB04 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C32A
Rated operational current at 50 °C29A
Rated operational current at 60 °C26A
Rated insulation voltage600V
Minimum settable current (% of Ie)10%
3RW3027-2BB04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24V
Rated voltage at 60 Hz24V
Main circuit terminal typespring-loaded terminals
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
3RW3027-2BB04 — Protection & Features
ParameterValue
Motor overload protectionNo
Thermistor motor protectionNo
Adjustable current limitationNo
Inside-delta connectionNo
Intrinsic device protectionNo
Pollution degree3, acc. to IEC 60947-4-2
3RW3027-2BB04 — Mechanical
ParameterValue
Height150mm
Width45mm
Depth150mm
Mounting positionWith vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° tiltable to the front and back
Fastening methodscrew and snap-on mounting
Mounting clearance, top60mm
Mounting clearance, bottom40mm
Mounting clearance, side15mm
3RW3027-2BB04 — Environmental
ParameterValue
Operating temperature range-25 ... +60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

What the 32 A rating means on this SIRIUS soft starter

The 3RW3027-2BB04: That 40 °C baseline is the typical panel internal temperature; if your enclosure runs hotter, the continuous current ceiling drops — plan the motor FLA against the derated figure at your actual ambient, not the 32 A headline. The integrated bypass contact system means once the motor reaches full speed, the thyristors are shorted out by an internal contactor — no external bypass contactor to wire, and the silicon junctions cool to near-ambient during run. This is the main differentiator from a basic soft starter that leaves the SCRs in circuit and burns heat continuously.

Panel integration — size S0 and terminal style

Size S0 frame measures 150 mm high x 45 mm wide x 150 mm deep. That 45 mm width is a single 9 mm DIN-rail module pitch — it occupies one slot. Screw and snap-on mounting lets you either clip it onto the DIN rail or screw-fix it to a backplate; the snap-on is faster for panel builds. Spring-loaded terminals on both the main current circuit and the auxiliary/control circuit — no screwdriver required for the power wires or the 24 V control loop. The main circuit accepts 16 to 8 AWG; the auxiliary side takes 24 to 14 AWG. Solid conductors and ferruled stranded both lock in without retorquing. Clearance zones: 60 mm above, 40 mm below, 15 mm at the sides. Those are the ventilation gaps — stack them tighter and the thyristor heatsink loses airflow, pulling the derating curve down. The mounting position allows ±10° rotation and ±10° tilt forward/back, so you can angle it in a tight cabinet as long as the natural convection path isn't blocked.

What it doesn't do — external protection you must add

This soft starter has no motor overload protection, no intrinsic device protection, no adjustable current limitation, and no motor brake output. That means you need an external overload relay in the motor circuit, a separate upstream short-circuit protection device (MCCB or fuses), and a standalone brake controller if the application requires DC injection braking. The minimum load is 10 % — it won't start a motor that draws less than 3.2 A at 40 °C.

No official successor or cross-reference is listed, so the 3RW3027-2BB04 is the active part for new builds and MRO spares.

Frequently asked questions

What is the maximum motor cable length for 3RW3027-2BB04?

The maximum motor cable length is 300 m. Beyond that, voltage drop and reflected-wave effects on the thyristors become a risk — keep the run under 300 m or add a motor reactor.

Does 3RW3027-2BB04 include an integrated bypass contactor?

Yes, the integrated bypass contact system eliminates the need for an external bypass contactor. Once the motor is up to speed, the thyristors are shorted out, reducing heat dissipation in the enclosure.

MPN
3RW3027-2BB04