Siemens 3RW3037-2BB04 — Soft Starters

Siemens 3RW3037-2BB04 SIRIUS Soft Starter, 63 A, S2 Frame

MPN3RW3037-2BB04
Active

Siemens SIRIUS 3RW3037-2BB04 soft starter, S2 frame, 63 A at 40 °C, 50/60 Hz, 24 V control, integrated bypass contact system, screw and snap-on mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW3037-2BB04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW3037-2BB04 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C63A
Rated operational current at 50 °C58A
Rated operational current at 60 °C53A
Rated insulation voltage600V
Minimum settable current (% of Ie)10%
3RW3037-2BB04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24V
Rated voltage at 60 Hz24V
Main circuit terminal typescrew-type terminals
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-10%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-10%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
3RW3037-2BB04 — Protection & Features
ParameterValue
Motor overload protectionNo
Thermistor motor protectionNo
Adjustable current limitationNo
Inside-delta connectionNo
Intrinsic device protectionNo
Pollution degree3, acc. to IEC 60947-4-2
3RW3037-2BB04 — Mechanical
ParameterValue
Height160mm
Width55mm
Depth170mm
Mounting positionWith vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° tiltable to the front and back
Fastening methodscrew and snap-on mounting
Mounting clearance, top60mm
Mounting clearance, bottom40mm
Mounting clearance, side30mm
3RW3037-2BB04 — Environmental
ParameterValue
Operating temperature range-25 ... +60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

63 A motor starting — what the rating means for the install

The 3RW3037-2BB04: For a motor with a 50 A FLA at 40 °C ambient, this starter holds headroom through the derating curve without upsizing the frame. The integrated bypass contact system eliminates the external bypass contactor and its wiring — the thyristors fire only during the start ramp, then the bypass relay closes, shunting current away from the semiconductors. This cuts heat dissipation in the panel during run and extends the life of the power stack.

Panel fit — S2 frame, mounting, and clearances

The S2 frame measures 55 mm wide, 160 mm high, and 170 mm deep — a compact footprint that fits a 6-module-wide DIN rail slot. Screw and snap-on mounting lets you either clip it onto the rail or bolt it directly to the backplate; the snap-on feature speeds replacement in a panel where the rail is already populated. Clearance requirements: 60 mm above, 40 mm below, and 30 mm at the side. These are the minimum air gaps for airflow and wiring access — stack them tighter and the derating curve shifts. The mounting position allows ±10° rotation and ±10° tilt from vertical, useful when the panel has a sloped gland plate. Pollution degree 3 per IEC 60947-4-2 means the creepage distances are designed for conductive dust and occasional condensation — typical for a motor control centre in a cement plant or sawmill, not just a climate-controlled switchroom.

Wiring terminals and conductor sizing

Main circuit terminals accept stranded wire 2x (1.5... 25 mm²) — that covers everything from a 4 mm² motor feed up to a 25 mm² supply cable for the full 63 A rating. Screw-type terminals on the main current circuit — no cage-clamp or push-in on the power side. Torque the screws to the value on the nameplate; the clamping points are dual (front and back) so you can loop through or terminate two conductors per pole. Maximum motor cable length is 300 m — above that, the cable capacitance can cause the thyristors to self-trigger on the off half-cycle. For long runs, add an output reactor or keep the cable below this limit.

Frequently asked questions

Where can I buy the 3RW3037-2BB04 and get a price?

No stock-holding claim on this listing.

What is the 3RW3037-2BB04's depth for panel layout?

The depth is 170 mm, with a width of 55 mm and height of 160 mm. The S2 frame fits a standard DIN-rail slot with the clearance requirements listed above.

MPN
3RW3037-2BB04