Siemens 3RW4026-2TB04

Siemens 3RW4026-2TB04 SIRIUS Soft Starter, 25 A, Size S0

MPN 3RW4026-2TB04
Active

Siemens SIRIUS 3RW4026-2TB04 soft starter, Size S0, 25 A at 40 °C, 50/60 Hz, 600 V insulation, spring-loaded terminals, integrated bypass, screw and snap-on mounting.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW4026-2TB04 specifications
ParameterValue
Mountingscrew and snap-on mounting
Depth155 mm
Width45 mm
Height150 mm

Product details

The 3RW4026-2TB04: Spring-loaded terminals on both the main current circuit and the auxiliary/control circuit mean no screw torque to check; strip and insert solid or ferruled stranded wire up to 2.5 mm². Clearance: 60 mm above, 40 mm below, 15 mm at the side for airflow — the derating curve starts at 40 °C ambient, so pack the cabinet with that in mind.

Current derating and the integrated bypass — what the 25 A rating actually means

An integrated bypass contact system closes after start-up, shunting the thyristors and cutting heat dissipation in the cabinet during run — this is what lets the S0 frame handle 25 A continuous without a fan at 40 °C. Adjustable current limitation lets you set the start current between 20 % and 100 % of the soft starter's rated current, matching the motor's inrush characteristic without oversizing the starter.

Active production — no end-of-life watch needed

Motor overload protection and intrinsic device protection are built in — no separate overload relay needed for most applications, which simplifies the BOM and panel wiring. Insulation voltage rated 600 V, pollution degree 3 per IEC 60947-4-2 — suitable for industrial environments with conductive dust or condensation.

Mounting position and cable length constraints

With the optional fan, the unit can be mounted on a vertical surface and rotated ±90° or tilted ±22.5° front-to-back; without the fan, rotation is limited to ±10°. Maximum motor cable length is 300 m — beyond that, capacitive charging current from the cable can interfere with the thyristor firing and cause nuisance trips. External reset input and a red LED fault signal give the technician a clear indication and remote reset capability without opening the panel door.