Skip to main content
Siemens 3RW4047-2BB04 — Soft Starters

Siemens 3RW4047-2BB04 SIRIUS Soft Starter, 106 A

MPN3RW4047-2BB04
Active

Siemens SIRIUS 3RW4047-2BB04 soft starter, Size S3, 106 A at 40 °C, 24 V AC/DC control voltage, screw-type terminals, thyristor-based motor overload protection.

$805.18Ref. price · indicative, final on quote
StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW4047-2BB04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW4047-2BB04 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C106A
Rated operational current at 50 °C98A
Rated operational current at 60 °C90A
Rated insulation voltage600V
Minimum settable current (% of Ie)20%

Control & Connection

3RW4047-2BB04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24V
Rated voltage at 60 Hz24V
Main circuit terminal typescrew-type terminals
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%

Protection & Features

3RW4047-2BB04 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionNo
Adjustable current limitationYes
Inside-delta connectionNo
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW4047-2BB04 — Mechanical
ParameterValue
Height170mm
Width70mm
Depth190mm
Mounting positionWith additional fan: With vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back Without additional fan: With vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° t
Fastening methodscrew and snap-on mounting
Mounting clearance, top60mm
Mounting clearance, bottom40mm
Mounting clearance, side30mm

Environmental

3RW4047-2BB04 — Environmental
ParameterValue
Operating temperature range-25 ... +60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

Rated current and thermal derating — 106 A at 40 °C

The 3RW4047-2BB04: This derating curve sets the usable motor FLA for a given enclosure temperature — at 50 °C ambient, a 98 A motor is the ceiling, not 106 A. The control circuit is 24 V AC/DC, 50/60 Hz, with a 20% minimum load requirement — below that, the thyristor firing angle may not maintain conduction.

Mounting and panel integration — Size S3, screw and snap-on

Size S3 frame: 170 mm high, 70 mm wide, 190 mm deep. Fastening method is screw and snap-on mounting to DIN rail. Clearance requirements: 60 mm upwards, 40 mm downwards, 30 mm at the side — these are the minimum air gaps for heat dissipation and wiring access. Mounting position is flexible: with an additional fan, the unit can be mounted on a vertical surface with +/-90° rotation and +/-22.5° tilt front/back. Without the fan, the envelope tightens to +/-10° rotation and +/-10° tilt. The derating temperature threshold is 40 °C — above that, the current ratings in the spec table apply.

Terminal capacity and wiring — screw-type, dual clamping points

Main circuit terminals accept stranded wire 2x (10... 70 mm²) and finely stranded 2x (10... 50 mm²). Both front and back clamping points accept 2x (10... 1/0) AWG; using both clamping points together accepts 10... 2/0 AWG. Maximum wire length to the motor is 300 m. The insulation voltage is rated 600 V, with pollution degree 3 per IEC 60947-4-2. This means the unit is designed for industrial environments where conductive pollution or dry non-conductive pollution that becomes conductive due to condensation is expected.

Motor protection and control features

Built-in motor overload protection and intrinsic device protection are standard. Adjustable current limitation allows setting the starting current below the locked-rotor value. An external reset input is provided for remote fault recovery. The soft starter does not support inside-delta circuit configuration — it is a standard in-line connection.

The SIRIUS brand designation and Size S3 frame are consistent across the 3RW40 series for this rating class.

Frequently asked questions

What is the rated current of 3RW4047-2BB04 at different temperatures?

These values set the maximum motor FLA for the given enclosure ambient temperature.

What control voltage does 3RW4047-2BB04 require?

The control circuit operates at 24 V AC/DC, 50/60 Hz. The minimum load requirement is 20% — below this threshold the thyristor firing angle may not maintain proper conduction.