Siemens 3RW4423-1BC36 SIRIUS Soft Starter, 62A, 690V

MPN 3RW4423-1BC36

Siemens SIRIUS soft starter, 3RW4423-1BC36, 62 A at 40 °C, 690 V insulation voltage, integrated bypass, adjustable current limitation.

$2,116.00 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW4423-1BC36 specifications
ParameterValue
Mountingscrew fixing
Depth270 mm
Width170 mm
Height192 mm

Product details

The Siemens SIRIUS 3RW4423-1BC36 is a soft starter rated 62 A at 40 °C, with an insulation voltage of 690 V and an operating frequency of 50 to 60 Hz. It includes an integrated bypass contact system and adjustable current limitation, plus motor overload and intrinsic device protection.

Above 40 °C, derate to 55 A at 50 °C and 50 A at 60 °C — plan your enclosure cooling if the ambient exceeds 40 °C. The 690 V insulation voltage (pollution degree 3 per IEC 60947-4-2) means it can be used on 400 V and 480 V systems with margin, but verify the line-to-line voltage does not exceed 690 V. The integrated bypass contact system eliminates the need for an external bypass contactor, reducing panel wiring and heat dissipation during run. Adjustable current limitation lets you set the starting current between 8% and 100% of the rated motor current — useful for soft-starting loads that need a controlled ramp. Mounting is screw fixing with a vertical surface orientation; the unit can be rotated ±90° or tilted ±22.5° front/back. Clearance requirements: 100 mm above, 75 mm below, 5 mm at the sides — tight side clearance helps in dense panels.

Wiring and connections

Main current circuit uses box terminals accepting stranded wire 2x (4 to 50 mm²) or solid 2x (0.5 to 2.5 mm²). Auxiliary and control circuits use screw-type terminals for 2x (20 to 14 AWG). Maximum wire length from the soft starter to the motor is 500 m — sufficient for most industrial layouts but check if your run exceeds that. The inside-delta circuit configuration is supported, which can reduce the starter's current rating requirement for six-lead motors.

Protection and diagnostics

Motor overload protection is built in, along with intrinsic device protection (e.g., thyristor overtemperature). An external reset input allows remote fault reset. A display provides fault signal indication — no need to add a separate annunciator.