Siemens 3RW4424-3BC36 — Soft Starters

Siemens 3RW4424-3BC36 SIRIUS Soft Starter, 81 A, 690 V

MPN3RW4424-3BC36

Siemens SIRIUS 3RW4424-3BC36 soft starter, 81 A at 40 °C, 690 V insulation voltage, 50/60 Hz, integrated bypass, inside-delta capable, screw fixing, 192 x 170 x 270 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW4424-3BC36 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW4424-3BC36 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C81A
Rated operational current at 50 °C73A
Rated operational current at 60 °C64A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%
3RW4424-3BC36 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz115V
Rated voltage at 60 Hz115V
Main circuit terminal typebox terminal
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%
3RW4424-3BC36 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW4424-3BC36 — Mechanical
ParameterValue
Height192mm
Width170mm
Depth270mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm
3RW4424-3BC36 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

Panel fit and derating reality

The 3RW4424-3BC36 occupies 192 mm height by 170 mm width by 270 mm depth, screw-fixed to the backplate — not DIN-rail snap-on, so budget four corner fasteners and a drill template.

Wiring and termination

Main power circuit uses box terminals accepting 2x (4... 50 mm²) stranded — that covers most motor cables up to 95 A class. Maximum motor cable length is 500 m — beyond that, capacitive charging current from the cable can interfere with the soft starter's firing circuit; keep runs under that for reliable starting.

Motor protection and control features

Built-in motor overload protection and intrinsic device protection mean no separate overload relay is needed for most applications — the soft starter handles thermal memory and fault lockout internally. Adjustable current limitation lets you cap starting current below the supply transformer or generator rating — set it as a percentage of the motor FLA, and the thyristors clip the current envelope. Minimum load is 8 % of the rated current — below that, the motor may not generate enough back-EMF for the soft starter to detect the end of start; light-load applications need a check against this threshold.

Inside-delta and bypass — what they mean for the cabinet

Inside-delta wiring (six-wire connection) reduces the current through each thyristor to 58 % of the line current — useful when the motor is far from the panel and cable sizing is tight, or when the soft starter's rating is marginal for the motor FLA. Integrated bypass contact system closes after the start ramp, taking the thyristors out of the circuit for steady-state running — this eliminates thyristor conduction losses and keeps the enclosure cooler during continuous duty.

Frequently asked questions

Can the 3RW4424-3BC36 be wired in inside-delta configuration?

Yes, it supports inside-delta (six-wire) connection, which reduces thyristor current to 58 % of line current.

What compliance documentation does Siemens provide for the 3RW4424-3BC36?

The soft starter is designed to IEC 60947-4-2, pollution degree 3, with an insulation voltage of 690 V. Standard Siemens documentation includes the declaration of conformity and CE marking; UL/CSA listing should be confirmed per the specific variant.

MPN
3RW4424-3BC36