Siemens 3RW4424-3BC46 — Soft Starters

Siemens 3RW4424-3BC46 Soft Starter, 81 A, 230 V, SIRIUS

MPN3RW4424-3BC46

Siemens SIRIUS 3RW4424-3BC46 soft starter, 81 A at 40 °C, 230 V AC, 50/60 Hz, inside-delta circuit, integrated bypass, spring-loaded terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW4424-3BC46 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW4424-3BC46 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C81A
Rated operational current at 50 °C73A
Rated operational current at 60 °C64A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%
3RW4424-3BC46 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz230V
Rated voltage at 60 Hz230V
Main circuit terminal typebox terminal
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%
3RW4424-3BC46 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW4424-3BC46 — Mechanical
ParameterValue
Height192mm
Width170mm
Depth270mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm
3RW4424-3BC46 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

81 A at 40 °C — the derating curve sets your panel budget

The 3RW4424-3BC46: That 21 % drop from 40 to 60 °C means the panel ventilation and adjacent heat sources directly govern whether this starter holds its full current rating in your enclosure. Inside-delta wiring reduces the current through each thyristor leg to 58 % of the line current — so this 81 A unit can start a motor with a nominal FLA well above 81 A when wired inside-delta. Confirm the motor winding configuration before specifying; the starter supports both standard and inside-delta connections. Integrated bypass contact system eliminates the need for an external bypass contactor — the bypass closes after the start ramp, shunting the thyristors and dropping the heat load to near zero during run. This saves panel space and wiring compared to a starter-plus-bypass combination.

Mounting, wiring, and clearance — what fits in the panel

Dimensions are 270 mm deep, 170 mm wide, 192 mm high — a compact footprint for the 81 A rating. Screw fixing to the mounting plate; the unit can be rotated ±90° on a vertical surface and tilted ±22.5° front-to-back, giving flexibility in tight enclosures. Clearance requirements: 100 mm above, 75 mm below, 5 mm at the sides. The top clearance is the critical one — it allows hot air from the thyristor heatsink to rise without recirculating. Skimping on the 100 mm overhead will force derating beyond the published curve. Main current circuit uses box terminals accepting 2x (4 … 50 mm²) stranded or 2x (10 … 1/0) AWG.

Protection and diagnostics — built-in, no add-ons

Motor overload protection and intrinsic device protection (thyristor overtemperature, phase imbalance, stalled rotor) are integrated. No external overload relay or motor protection circuit breaker is required for the starter itself — the 3RW44 series handles it internally. Adjustable current limitation lets you set the start current anywhere from 0 to the rated value — useful for soft-starting conveyors or pumps where a hard limit on inrush protects downstream mechanicals. Minimum load is 8 % of rated current, so it can start lightly loaded motors without dropping out. Fault signal is displayed on the unit itself — a local display shows the fault code, which speeds troubleshooting on the floor without needing a laptop. External reset input allows remote clearing from a PLC or pushbutton station.

Environmental and electrical ratings — industrial duty

Pollution degree 3 per IEC 60947-4-2 — the standard for industrial environments where conductive dust or condensation can occur. Insulation voltage rated 690 V, giving headroom on 400/480 V systems. Operating frequency 50 … 60 Hz — one unit covers both line frequencies. Storage temperature range -25 … +80 °C, operation up to 60 °C ambient. Maximum motor cable length 500 m — long enough for most pump and conveyor runs without output reactors.

Frequently asked questions

What is the inside-delta circuit and why does it matter?

Inside-delta wiring connects the soft starter in series with each motor winding rather than in the line. This reduces the current through each thyristor to 58 % of the line current, so the 81 A unit can start a motor with a higher FLA when wired inside-delta. Confirm the motor winding configuration before specifying.