Siemens 3RW4425-3BC34

Siemens 3RW4425-3BC34 Soft Starter, 99A, SIRIUS Series

MPN 3RW4425-3BC34

Siemens SIRIUS 3RW4425-3BC34 soft starter, 99 A at 40 °C, 690 V insulation voltage, integrated bypass, adjustable current limitation, screw fixing, 170 x 192 x 270 mm (W x H x D).

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW4425-3BC34 specifications
ParameterValue
Mountingscrew fixing
Depth270 mm
Width170 mm
Height192 mm

Product details

Panel fit and mounting constraints

The 3RW4425-3BC34 measures 170 mm wide by 192 mm high by 270 mm deep and mounts via screw fixing, not DIN rail — plan for four drilled holes on the backplate. Mounting position allows vertical surface with ±90° rotation and ±22.5° tilt front-to-back, giving flexibility in tight enclosures. Clearance requirements: 100 mm above, 75 mm below, 5 mm at the sides — the top gap is critical for heat plume rise from the thyristor stack.

Current ratings and thermal derating

Minimum load is 8 % of the rated current — below that the soft starter may not trigger the thyristors reliably; check the motor magnetising current against this floor.

Wiring and termination details

Auxiliary and control circuit wiring uses spring-loaded terminals for 2x (24... 16 AWG) — no screw tightening, just push in for solid or ferruled stranded. Maximum motor cable length is 500 m — beyond that, reflected wave voltages on the motor terminals can stress the winding insulation, especially on 690 V systems.

Protection and control features

Integrated bypass contact system means the thyristors are shorted out after start — no continuous heat dissipation in the power stack during run, so the enclosure thermal load drops significantly. Adjustable current limitation lets you set the start current between the motor's no-load and locked-rotor values — useful for soft-starting conveyors or pumps without tripping upstream protection. Motor overload protection and intrinsic device protection are both built in — the soft starter monitors its own heatsink temperature and the motor thermal model, so an external overload relay is optional. Inside-delta wiring is supported — connect the soft starter in the delta loop of a six-lead motor to reduce the current rating needed per phase by about 58 %.

Environmental and compliance data

Pollution degree 3 per IEC 60947-4-2 — suitable for industrial environments with conductive dust or occasional condensation; the enclosure should maintain at least IP54 around the unit.

MPN
3RW4425-3BC34