Siemens 3RW4426-3BC44 SIRIUS Soft Starter, 133 A, 230 V

MPN3RW4426-3BC44

Siemens SIRIUS 3RW4426-3BC44 soft starter, 133 A at 40 °C, 230 V AC, 50/60 Hz, integrated bypass, adjustable current limitation, screw fixing, 170 x 192 x 270 mm.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW4426-3BC44 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW4426-3BC44 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C133A
Rated operational current at 50 °C118A
Rated operational current at 60 °C102A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%

Control & Connection

3RW4426-3BC44 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz230V
Rated voltage at 60 Hz230V
Main circuit terminal typebox terminal
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%

Protection & Features

3RW4426-3BC44 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW4426-3BC44 — Mechanical
ParameterValue
Height192mm
Width170mm
Depth270mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm

Environmental

3RW4426-3BC44 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

Current ratings and thermal derating profile

The 3RW4426-3BC44: This derating curve sets the real-world continuous current capacity inside a warm panel — the 133 A figure applies only at the 40 °C reference point, and the actual motor FLA must fall within the derated value at the enclosure's internal ambient. The insulation voltage rating of 690 V provides headroom above the 230 V operating level, while the operating frequency range of 50 to 60 Hz covers global line supplies without derating.

Integrated bypass and adjustable current limit

An integrated bypass contact system switches the thyristors out of the circuit once the motor reaches full speed, eliminating SCR conduction losses during continuous run. This directly reduces heat dissipation inside the panel and improves overall system efficiency compared to soft starters that keep the thyristors in circuit. Adjustable current limitation allows tuning the starting current peak between the minimum load threshold of 8% and the full rated current. For applications with light initial loads or conveyors that must not jolt, this parameter sets the acceleration torque profile.

Mounting envelope and panel integration

The 3RW4426-3BC44 measures 170 mm wide by 192 mm high by 270 mm deep, with screw-fixing mounting. Minimum clearance requirements are 100 mm upward, 75 mm downward, and 5 mm at the sides for airflow and cable bending radius. The mounting position allows vertical surface orientation with ±90° rotation and ±22.5° tilt front-to-back, giving flexibility in tight panel layouts while maintaining the derating and cooling assumptions.

Wiring terminals and cable sizing

Main current circuit connections use box terminals accepting stranded cable sizes 2x (4 to 50 mm²) or AWG 10 to 1/0 using both clamping points. The back and front clamping points each accept AWG 10 to 2/0, providing options for parallel feeds or larger single conductors. Auxiliary and control circuits terminate via spring-loaded terminals accepting solid wire 2x (0.25 to 1.5 mm²) or AWG 24 to 16. Maximum motor cable length is 500 m, which governs installation in distributed motor centres where the soft starter is remote from the load.

Environmental and protection features

Operating temperature range is up to 60 °C during operation, with storage from -25 to +80 °C. Built-in motor overload protection and intrinsic device protection are standard, with an external reset input and a display for fault signal indication. The inside-delta circuit configuration is supported for motors wired in delta during start.

Frequently asked questions

What is the continuous current rating of 3RW4426-3BC44 at typical panel ambient?

Rated 133 A at 40 °C, but derates to 118 A at 50 °C and 102 A at 60 °C. For a panel running at 50 °C internal ambient, the motor FLA must not exceed 118 A continuous.

Does 3RW4426-3BC44 include an internal bypass contactor?

Yes, it has an integrated bypass contact system that removes the thyristors from the circuit after start, reducing continuous power dissipation and heat in the enclosure.

What wiring terminals does 3RW4426-3BC44 use for main and control circuits?

Main circuit connections use box terminals accepting stranded 4 to 50 mm² or AWG 10 to 1/0. Auxiliary and control circuits use spring-loaded terminals for solid 0.25 to 1.5 mm² or AWG 24 to 16.

What clearance is needed around 3RW4426-3BC44 in a panel?

Minimum clearances are 100 mm above, 75 mm below, and 5 mm at the sides for ventilation and cable access.