Siemens 3RW4426-3BC45 — Soft Starters

Siemens 3RW4426-3BC45 SIRIUS Soft Starter, 133 A, 690 V

MPN3RW4426-3BC45

Siemens SIRIUS 3RW4426-3BC45 soft starter, 133 A at 40 °C, 690 V insulation voltage, 50/60 Hz, integrated bypass, screw fixing, box terminal main circuit.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW4426-3BC45 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW4426-3BC45 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C133A
Rated operational current at 50 °C118A
Rated operational current at 60 °C102A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%

Control & Connection

3RW4426-3BC45 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz230V
Rated voltage at 60 Hz230V
Main circuit terminal typebox terminal
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%

Protection & Features

3RW4426-3BC45 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW4426-3BC45 — Mechanical
ParameterValue
Height192mm
Width170mm
Depth270mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm

Environmental

3RW4426-3BC45 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

Current derating and bypass — what drives the real rating

The 3RW4426-3BC45: Rated 133 A at 40 °C, derated to 118 A at 50 °C and 102 A at 60 °C — the ambient inside the panel sets the usable current, not the nameplate number. Integrated bypass contact system means the thyristors are shorted out once the motor is up to speed, cutting heat dissipation in the enclosure and letting the soft starter run cooler in continuous duty.

Mounting, clearances, and terminal wiring

Dimensions 170 mm wide × 192 mm high × 270 mm deep; screw fixing to the back panel, not DIN rail. Mounting position allows ±90° rotation and ±22.5° tilt front-to-back. Minimum clearance: 100 mm above, 75 mm below, 5 mm at the sides — plan the gland plate and busbar routing to keep airflow open. Main circuit uses box terminals accepting 2× (4 … 50 mm²) stranded or 2× (10 … 1/0 AWG).

Protection, control, and inside-delta wiring

Built-in motor overload protection and intrinsic device protection reduce the need for separate relays in the starter bucket. Adjustable current limitation lets you set the starting torque profile per load. Inside-delta circuit capability — for six-lead motors, the soft starter can be wired inside the delta to run at a lower current rating per phase, saving panel space and cost. Minimum load is 8 % — light-load applications like small pumps or fans need to stay above this threshold to avoid misfiring the thyristors. External reset input and a fault display simplify remote troubleshooting without opening the panel door.

Insulation, environment, and wire length

Rated insulation voltage 690 V with pollution degree 3 per IEC 60947-4-2 — suitable for industrial environments with conductive dust or condensation. Operating temperature range –25 to +60 °C during operation, storage from –25 to +80 °C. Maximum motor cable length 500 m — stay under this to avoid reflected-wave trips on long runs.

Frequently asked questions

What is the maximum current at 60 °C ambient?

102 A at 60 °C, down from 133 A at 40 °C. The integrated bypass reduces continuous heat load inside the panel.

Can this soft starter be wired in inside-delta configuration?

Yes, inside-delta circuit is supported. This lets you use a lower-rated unit for six-lead motors, reducing cost and panel space.

What terminals does the control circuit use?

The main circuit uses box terminals for 2× (4 … 50 mm²) stranded.