Siemens 3RW4427-1BC46 — Soft Starters

Siemens 3RW4427-1BC46 SIRIUS Soft Starter, 161 A at 40 °C

MPN3RW4427-1BC46

Siemens SIRIUS 3RW4427-1BC46 soft starter, 161 A at 40 °C, 690 V insulation voltage, 50/60 Hz, integrated bypass contact, thyristor-based, screw fixing.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW4427-1BC46 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW4427-1BC46 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C161A
Rated operational current at 50 °C142A
Rated operational current at 60 °C125A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%
3RW4427-1BC46 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz230V
Rated voltage at 60 Hz230V
Main circuit terminal typebox terminal
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%
3RW4427-1BC46 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW4427-1BC46 — Mechanical
ParameterValue
Height192mm
Width170mm
Depth270mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm
3RW4427-1BC46 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

Current ratings that decide the motor match

The 3RW4427-1BC46: Rated 161 A at 40 °C, derating to 142 A at 50 °C and 125 A at 60 °C. The 40 °C figure is the baseline — above that, the thyristor junction temperature limits the continuous current. For a motor nameplate of 150 A FLA in a 40 °C ambient, this unit holds headroom; in a 50 °C panel, the 142 A ceiling still covers most 132 kW (400 V) machines. The 8% minimum load setting means it handles lightly loaded conveyors or pumps without dropping out.

Integrated bypass and wiring constraints

An integrated bypass contact system means the thyristors are shorted out once the motor reaches full speed — no external bypass contactor needed, and the heat load in the panel drops to near zero during run. The main circuit uses box terminals accepting stranded 4–50 mm² or solid 0.5–2.5 mm². Control and auxiliary circuits use screw-type terminals sized for 20–14 AWG. Maximum motor cable length is 500 m — beyond that, reflected wave spikes on the cable can stress the thyristor stack.

Mounting and clearance for panel layout

Screw fixing to a vertical mounting surface, with ±90° rotation and ±22.5° tilt front/back allowed. Dimensions: 170 mm wide, 192 mm high, 270 mm deep. Clearance requirements: 100 mm above, 75 mm below, 5 mm at the sides — the top clearance is the critical one for heat plume rise from the heatsink. Pollution degree 3 per IEC 60947-4-2 means it's rated for the conductive-dust environment typical of industrial panels.

Inside-delta wiring and adjustable current limit

Supports inside-delta circuit connection — the soft starter sits in the delta legs of a six-lead motor, reducing the per-phase current the thyristors carry by a factor of √3 compared to in-line wiring. Adjustable current limitation lets you set the start current between the motor's no-load and locked-rotor values, which is useful for conveyors that need a controlled acceleration ramp without tripping upstream protection. Motor overload protection is built in, so a separate overload relay is not required.

Control supply and fault indication

The unit has a display for fault signals and supports external reset — useful for remote reset in an unmanned conveyor zone. Storage temperature range is -25 to +80 °C; during operation the ambient must stay at or below 60 °C. Derating temperature threshold is 40 °C — above that, the output current must be reduced per the derating curve.

Frequently asked questions

What compliance documentation is available for the 3RW4427-1BC46?

The evidence does not list specific compliance marks (RoHS, REACH, UL, IEC) for this order code. The product is designed to IEC 60947-4-2 (pollution degree 3) and carries the SIRIUS brand. Compliance documentation should be confirmed at RFQ.

MPN
3RW4427-1BC46