Siemens 3RW4427-3BC36

Siemens 3RW4427-3BC36 SIRIUS Soft Starter, 161 A, 690 V

MPN 3RW4427-3BC36

Siemens SIRIUS 3RW4427-3BC36 soft starter, 161 A at 40 °C, 690 V insulation voltage, 50/60 Hz, integrated bypass, adjustable current limitation, inside-delta circuit, screw fixing.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW4427-3BC36 specifications
ParameterValue
Mountingscrew fixing
Depth270 mm
Width170 mm
Height192 mm

Product details

Current derating and thermal budget

The 3RW4427-3BC36: Minimum load is 8 % of the rated current — below that the soft starter may not trigger the thyristors reliably, so check the motor magnetising current against this floor.

Bypass and protection topology

Integrated bypass contact system means the thyristors are shorted out after start, eliminating continuous conduction losses — the 161 A rating applies to the bypass path, not just the silicon. Built-in motor overload protection and intrinsic device protection reduce external relay count; adjustable current limitation lets you set the start ramp ceiling without a separate current-limiting reactor.

Wiring and panel fit

Envelope is 170 mm wide, 192 mm high, 270 mm deep — screw fixing, not DIN rail. Mounting position allows ±90° rotation and ±22.5° tilt front-to-back, which helps in tight retrofit cabinets. Clearance: 100 mm upward, 75 mm downward, 5 mm at the sides — the side gap is tight; forced airflow or a wider cabinet may be needed above 40 °C.

Inside-delta wiring and motor lead length

Inside-delta circuit configuration is supported — this places the soft starter in the delta legs of a six-lead motor, reducing the current rating needed by about 58 % compared to in-line wiring. Useful for retrofitting a smaller unit onto an existing motor. Maximum motor cable length is 500 m — beyond that, reflected wave voltage spikes at the motor terminals may exceed the thyristor blocking voltage, especially on 690 V systems.

Environmental and compliance

Pollution degree 3 per IEC 60947-4-2 — conductive pollution or dry non-conductive pollution that becomes conductive due to condensation is expected. The enclosure seal and internal creepage distances are designed for this. Storage temperature range -25 to +80 °C; operation up to 60 °C ambient. Insulation voltage rated 690 V, operating frequency 50/60 Hz.

MPN
3RW4427-3BC36