Siemens 3RW4436-2BC44 — Soft Starters

Siemens 3RW4436-2BC44 SIRIUS Soft Starter, 281A

MPN3RW4436-2BC44

Siemens SIRIUS soft starter, 3RW4436-2BC44, 281 A rated at 40 °C, 690 V insulation voltage, 50/60 Hz, thyristor-based motor overload protection.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW4436-2BC44 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW4436-2BC44 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C281A
Rated operational current at 50 °C251A
Rated operational current at 60 °C217A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%

Control & Connection

3RW4436-2BC44 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz230V
Rated voltage at 60 Hz230V
Main circuit terminal typebusbar connection
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%

Protection & Features

3RW4436-2BC44 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW4436-2BC44 — Mechanical
ParameterValue
Height200mm
Width170mm
Depth270mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm

Environmental

3RW4436-2BC44 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

What this 281 A soft starter does on the line

The Siemens 3RW4436-2BC44 is a SIRIUS soft starter rated 281 A at 40 °C, 251 A at 50 °C, and 217 A at 60 °C, with an insulation voltage of 690 V and operating frequency of 50 to 60 Hz. Above that, you derate: at 50 °C you lose about 11% of the rated current, at 60 °C about 23%. If the panel runs hot — common in a crowded MCC or near a dryer section — size the motor FLA against the derated number, not the headline 281 A.

The unit measures 200 mm high by 170 mm wide by 270 mm deep and uses screw fixing to a vertical mounting surface. It can be rotated ±90° or tilted ±22.5° front-to-back, so it fits in a swing-frame or a tight backpanel without forcing a custom bracket. Clearance requirements: 100 mm above, 75 mm below, 5 mm at the sides — the side gap is tight enough that adjacent devices can sit nearly flush, but the vertical gap matters for convection cooling of the thyristor stack. Main circuit connection is via busbar; the terminal range accepts 25 to 120 mm² stranded or 4 to 250 kcmil. For auxiliary contacts, the terminals take 2x (0.25 to 1.5 mm²) solid or 2x (24 to 16 AWG). The maximum wire length from the soft starter to the motor is 500 m — beyond that, capacitive charging current can interfere with the thyristor firing and the internal bypass.

Protection and control features

The soft starter includes motor overload protection and intrinsic device protection — meaning it can protect both the motor and its own thyristors from overcurrent and overtemperature without an external overload relay. The adjustable current limitation lets you set the starting current between 8% and 100% of the rated current, which is useful for soft-starting pumps or conveyors where you need to limit inrush to avoid tripping upstream breakers or mechanical shock to the load. An external reset input is provided, so the starter can be reset remotely from a PLC or control room — no need to walk to the panel after a fault. The display version shows fault signals on the unit itself, which helps a technician on the floor identify the reason for a trip without a laptop. It supports inside-delta circuit wiring, which reduces the current through the thyristors to 58% of the line current — useful for derating the unit on a high-inertia load where the motor FLA exceeds the soft starter's rating.

Environmental and pollution rating

Storage temperature range is -25 to +80 °C; during operation the ambient limit is 60 °C. The derating temperature threshold is 40 °C, above which you must reduce the rated current as shown in the spec table.

Frequently asked questions

Is the 3RW4436-2BC44 discontinued?

Buyers must know if the part is still available or if they need to design in the successor.

What is the direct successor to 3RW4436-2BC44?

Engineers and buyers need the exact replacement part number for sourcing and design updates.

Can I replace 3RW4436-2BC44 with 3RW5536-2HA14 without modification?

Ensures compatibility in panel space, wiring, and performance to avoid re-engineering costs.

Where can I buy the 3RW4436-2BC44 soft starter?

Sourcing buyers need to find authorized distributors and current stock.

What are the specifications (162A, 90kW) of the 3RW4436-2BC44?

Design engineers validate fit for motor protection and control requirements.

What is the price of the 3RW4436-2BC44 soft starter?

Buyers need pricing for budgeting and comparing with the successor.

MPN
3RW4436-2BC44