Siemens 3RW4436-2BC45 SIRIUS Soft Starter, 281 A, 690 V

MPN3RW4436-2BC45

Siemens SIRIUS 3RW4436-2BC45 soft starter, 281 A at 40 °C, 690 V insulation voltage, 50/60 Hz, thyristor-based, adjustable current limitation, inside-delta circuit, screw fixing, 270 mm depth.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW4436-2BC45 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW4436-2BC45 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C281A
Rated operational current at 50 °C251A
Rated operational current at 60 °C217A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%

Control & Connection

3RW4436-2BC45 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz230V
Rated voltage at 60 Hz230V
Main circuit terminal typebusbar connection
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%

Protection & Features

3RW4436-2BC45 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW4436-2BC45 — Mechanical
ParameterValue
Height200mm
Width170mm
Depth270mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm

Environmental

3RW4436-2BC45 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

Rated current and thermal derating — what 281 A means on the panel

The 3RW4436-2BC45: Thyristor-based output with adjustable current limitation lets you set the start ramp peak below the motor's locked-rotor draw, reducing mechanical shock on the load train. The inside-delta circuit configuration means the soft starter can be wired in the motor delta loop, reducing the unit's current rating requirement compared to in-line connection.

Mounting and connection — screw-fixed, multi-cable entry

Mounting position allows vertical surface with ±90° rotation and ±22.5° tilt front/back — fits into tight panel layouts where the gland plate orientation is fixed. Fastening method is screw fixing, not DIN rail snap-on, so plan for drilled holes and M6 or M8 hardware. Main current circuit accepts busbar connection or cable: stranded 25–120 mm², finely stranded 16–95 mm², or AWG 4–250 kcmil. The front and back clamping points each handle 6–2/0 AWG; using both clamping points maxes at 2x 1/0 AWG. Clearance spaces: 100 mm upwards, 75 mm downwards, 5 mm at the side — essential for airflow and cable bending radius. Maximum wire length to the motor is 500 m; longer runs increase voltage drop and may cause nuisance overcurrent trips during start.

Protection and diagnostics — built-in overload and fault display

Motor overload protection is integrated, so a separate thermal overload relay is not needed for most installations. Intrinsic device protection (thyristor overtemperature, phase imbalance) is also included, reducing external monitoring hardware. Fault signal is shown on a display (not just a single LED), giving a readable code for troubleshooting — useful when the panel is remote from the operator station. External reset input allows remote clearing after a fault, avoiding a trip to the cabinet. Minimum load is 8% of the rated current — below that the soft starter may not detect the motor current correctly, so verify the no-load or light-load condition.

Compliance documentation includes IEC 60947-4-2 (pollution degree 3), operating frequency 50/60 Hz, and storage temperature range -25 to +80 °C.

Frequently asked questions

What is the closest pin-compatible alternative to 3RW4436-2BC45 in this Soft Starters family?

The 3RW4436-2BC45 is a current-production SIRIUS soft starter; any parametric substitute would require verifying the same current rating, inside-delta capability, and mounting footprint.

What compliance documentation does Siemens provide for 3RW4436-2BC45?

The unit complies with IEC 60947-4-2 (pollution degree 3) and is rated for 50/60 Hz operation. Storage temperature range is -25 to +80 °C; operating ambient up to 60 °C.