Siemens 3RW4443-2BC46 SIRIUS Soft Starter, 352 A at 40 °C

MPN3RW4443-2BC46

Siemens SIRIUS 3RW4443-2BC46 soft starter, 352 A at 40 °C, 312 A at 50 °C, 270 A at 60 °C, 690 V insulation voltage, 50/60 Hz, thyristor-based, inside-delta circuit, screw fixing, 298 mm depth, 210 mm width, 230 mm height.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW4443-2BC46 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW4443-2BC46 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C352A
Rated operational current at 50 °C312A
Rated operational current at 60 °C270A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%
3RW4443-2BC46 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz230V
Rated voltage at 60 Hz230V
Main circuit terminal typebusbar connection
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%
3RW4443-2BC46 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW4443-2BC46 — Mechanical
ParameterValue
Height230mm
Width210mm
Depth298mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm
3RW4443-2BC46 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

Active production, derated current profile

The 3RW4443-2BC46: The 40 °C figure is the reference for panel sizing; if your enclosure ambient runs above 40 °C, the 50 °C or 60 °C column is the one that governs the motor FLA match.

Thyristor stack and inside-delta wiring

Built around a thyristor power section — no mechanical contacts to weld or pit during the start cycle. The inside-delta circuit topology is supported, which lets you wire the soft starter between the motor windings rather than in the supply lines, reducing the per-phase current the unit carries by roughly 58 % for a given motor rating. Pollution degree 3 per IEC 60947-4-2 means it tolerates conductive dust and condensation typical in industrial panel environments.

Mounting and connection — panel layout constraints

Mounting position allows a vertical surface with ±90° rotation and ±22.5° tilt forward/back. Screw fixing to the backplate — no DIN-rail clip, so plan for drilled and tapped mounting points. Dimensions are 298 mm deep by 210 mm wide by 230 mm high; the depth is the dimension that governs enclosure depth, not the width. Main circuit connections accept busbar or cable: stranded 70–240 mm², finely stranded 50–240 mm², or AWG/kcmil from 2/0 up to 500 kcmil using both clamping points. The back clamping point takes 250–500 kcmil, the front takes 3/0–600 kcmil. Clearance requirements: 100 mm upwards, 75 mm downwards, 5 mm at the sides. The 5 mm side gap is tight — adjacent devices or cable ducts must not encroach into that zone for airflow and arc flash clearance.

Protection, display, and control features

Motor overload protection and intrinsic device protection are built in — no separate overload relay needed for the soft starter itself. Adjustable current limitation lets you set the start current below the full-load locked-rotor value, and the minimum load threshold is 8 % of the rated current. A display provides fault signal readout on the unit. External reset input is present, so the starter can be reset from a remote pushbutton or PLC digital output without opening the panel door. Maximum motor cable length is 500 m — relevant for installations where the starter is in an MCC room and the motor is at the far end of a long cable run. Storage temperature range is -25 to +80 °C; operating ambient max is 60 °C.

Frequently asked questions

What is the closest alternative to the 3RW4443-2BC46 in the SIRIUS soft starter family?

No official successor or direct cross-reference is recorded from Siemens. Within the SIRIUS 3RW44 series, the 3RW4443-2BC46 is a specific current rating tier (352 A at 40 °C); a lower or higher current variant in the same frame size would require a different order code. Confirm the motor FLA and ambient temperature against the derating table before selecting an alternative.

What compliance documentation is available for the 3RW4443-2BC46?

The part carries pollution degree 3 rating per IEC 60947-4-2. Standard Siemens declarations (CE, UKCA, RoHS, REACH) apply to the SIRIUS series; specific certification documents are issued against the serialized unit at time of manufacture. No UL or CSA listing is explicitly stated in the available spec record.

MPN
3RW4443-2BC46