Siemens 3RW4444-2BC36 — Soft Starters

Siemens 3RW4444-2BC36 Soft Starter, 433A, SIRIUS

MPN3RW4444-2BC36

Siemens SIRIUS 3RW4444-2BC36 soft starter, 433 A at 40 °C, 690 V insulation voltage, thyristor-based, inside-delta circuit capable, screw fixing.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW4444-2BC36 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW4444-2BC36 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C433A
Rated operational current at 50 °C372A
Rated operational current at 60 °C320A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%

Control & Connection

3RW4444-2BC36 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz115V
Rated voltage at 60 Hz115V
Main circuit terminal typebusbar connection
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%

Protection & Features

3RW4444-2BC36 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW4444-2BC36 — Mechanical
ParameterValue
Height230mm
Width210mm
Depth298mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm

Environmental

3RW4444-2BC36 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

433 A at 40 °C — the operating ceiling for full-load motor starting

The Siemens 3RW4444-2BC36 SIRIUS soft starter is rated 433 A at 40 °C ambient, which sets the maximum motor full-load current it can ramp up without exceeding its thermal limit.

Thyristor switching and inside-delta wiring

Built around thyristors for the main current path, this soft starter provides controlled voltage ramp starting to limit inrush current and mechanical shock to the driven load. The inside-delta circuit connection option reduces the current through the soft starter by a factor of √3 compared to standard in-line wiring — useful when the motor current exceeds the unit's rating but the soft starter can still handle the reduced phase current. Motor overload protection is integrated, so you can omit a separate overload relay in many installations. Adjustable current limitation lets you set the start current between 8% and the unit's full rating, matching the load's breakaway torque requirement.

Panel mounting and clearance requirements

Mounting is by screw fixing onto a vertical surface, with ±90° rotation and ±22.5° tilt allowance for panel layout flexibility. The footprint is 210 mm wide by 230 mm high, and the depth is 298 mm — that depth is the dimension to check for enclosure depth clearance, especially in shallow cabinets. Ventilation and safety spacing: 100 mm clearance required upwards, 75 mm downwards, and 5 mm at the sides. These gaps keep the heat from the thyristor stack from recirculating into the control electronics.

Field wiring and termination

Main circuit wiring accepts stranded conductors from 70 to 240 mm², finely stranded from 50 to 240 mm², and AWG/kcmil from 2/0 to 500 kcmil. For busbar connection, the main current circuit uses busbar connection points rather than cable lugs — a common preference in high-current switchgear where bus runs replace individual cables.

Sourced through authorized distribution channels. The unit carries pollution degree 3 per IEC 60947-4-2, suitable for industrial environments with conductive pollution.

Frequently asked questions

What is the maximum motor cable length for 3RW4444-2BC36?

The maximum wire length from the soft starter to the motor is 500 m. Beyond that, voltage drop and cable capacitance can affect the thyristor commutation and the motor terminal voltage profile.

Does 3RW4444-2BC36 support inside-delta wiring?

Yes, it is inside-delta circuit capable. This wiring topology places the soft starter in the delta legs of a delta-connected motor, reducing the current through each thyristor pair to 58% of the motor line current — a useful option when the motor FLA exceeds the unit's 433 A rating.