Siemens 3RW4444-2BC46 — Soft Starters

Siemens 3RW4444-2BC46 Soft Starter, 433 A, 690 V, SIRIUS

MPN3RW4444-2BC46

Siemens SIRIUS 3RW4444-2BC46 soft starter, 433 A at 40 °C, 690 V insulation voltage, 50/60 Hz, inside-delta circuit, thyristor, screw fixing, 230 x 210 x 298 mm.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW4444-2BC46 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW4444-2BC46 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C433A
Rated operational current at 50 °C372A
Rated operational current at 60 °C320A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%

Control & Connection

3RW4444-2BC46 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz230V
Rated voltage at 60 Hz230V
Main circuit terminal typebusbar connection
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%

Protection & Features

3RW4444-2BC46 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW4444-2BC46 — Mechanical
ParameterValue
Height230mm
Width210mm
Depth298mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm

Environmental

3RW4444-2BC46 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

Continuous current and the derating that matters

The 3RW4444-2BC46: That 40 °C figure is the baseline — in a closed panel with other heat sources, expect to budget for the 50 °C or 60 °C column unless you have forced ventilation. Insulation voltage rated 690 V, operating frequency 50…60 Hz. The 690 V ceiling means this unit handles 400 V line-to-line systems with margin; no voltage derating needed for standard 380–480 V grids.

Inside-delta wiring and current limitation

Supports inside-delta circuit configuration — the soft starter connects in the delta legs of a six-lead motor, reducing the line current the device carries relative to the motor full-load current. For a given motor, this lets a smaller-frame soft starter do the job. Adjustable current limitation lets you set the start current between 8% and 100% of the device rating. The 8% minimum load threshold means the thyristors may not fire reliably below that point — factor this into no-load commissioning or very light loads.

Panel layout and wiring constraints

Clearance requirements: 100 mm above, 75 mm below, 5 mm at the sides — these are for ventilation and arc-flash separation per IEC 60947-4-2. Main circuit accepts stranded 70…240 mm² or kcmil 2/0…500. Auxiliary connections take solid 0.25…1.5 mm². The main current circuit uses busbar connection — plan for busbar lugs, not cable lugs, on the power terminals. Dimensions 230 mm high, 210 mm wide, 298 mm deep. The depth is the largest envelope — ensure the enclosure depth accommodates the unit plus the 100 mm top clearance for cable bending and airflow.

Protection and diagnostics built in

Integrated motor overload protection eliminates the separate overload relay in many panels. Intrinsic device protection covers the soft starter itself against overtemperature and overcurrent. On-board display for fault signals — no external HMI needed for basic diagnostics. External reset input allows remote clearing of fault conditions. Pollution degree 3 per IEC 60947-4-2 — rated for industrial environments with conductive dust or occasional condensation. Storage temperature -25…+80 °C, operation up to 60 °C ambient.

Frequently asked questions

What is the continuous current rating at elevated ambient temperatures?

433 A at 40 °C, derated to 372 A at 50 °C, and 320 A at 60 °C. Use the 50 °C or 60 °C column if the soft starter shares a closed panel with other heat-generating devices.

Can this soft starter be wired in an inside-delta configuration?

Yes, it supports inside-delta circuit wiring. This connects the soft starter in the delta legs of a six-lead motor, reducing the line current the device carries relative to the motor FLA.

What compliance documentation does Siemens provide for 3RW4444-2BC46?

The device is designed to IEC 60947-4-2 (pollution degree 3) and carries the SIRIUS brand.

MPN
3RW4444-2BC46