Skip to main content
Siemens 3RW4453-2BC44 — Soft Starters

Siemens 3RW4453-2BC44 SIRIUS Soft Starter, 954 A at 40 °C

MPN3RW4453-2BC44

Siemens SIRIUS 3RW4453-2BC44 soft starter, 954 A at 40 °C, 690 V insulation voltage, 50/60 Hz, 3-phase, integrated bypass contact system, inside-delta circuit, screw fixing, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW4453-2BC44 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW4453-2BC44 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C954A
Rated operational current at 50 °C856A
Rated operational current at 60 °C759A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%
3RW4453-2BC44 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz230V
Rated voltage at 60 Hz230V
Main circuit terminal typebusbar connection
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%
3RW4453-2BC44 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW4453-2BC44 — Mechanical
ParameterValue
Height640mm
Width510mm
Depth290mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm
3RW4453-2BC44 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

Current rating and thermal derating — the real operating envelope

The 3RW4453-2BC44: The derating temperature threshold is 40 °C — above that, the continuous current drops linearly per the datasheet curve. For a panel with an internal ambient of 50 °C, budget 856 A as the usable ceiling; the 60 °C figure (759 A) applies only if the enclosure ventilation keeps the air around the unit below that limit. The insulation voltage is rated 690 V, with an operating frequency range of 50 to 60 Hz.

Integrated bypass and inside-delta topology

An integrated bypass contact system is built into the unit — once the motor reaches full speed, the thyristors are shorted out, eliminating heat dissipation from the semiconductor stack during continuous run. This means the enclosure thermal budget is set by the bypass contactor losses, not the silicon junction temperature. The unit supports inside-delta circuit wiring, which connects the soft starter in the delta legs of a six-lead motor. This reduces the current through each thyristor to 58% of the line current, effectively extending the current range of the unit without increasing the semiconductor die size. Verify the motor has six accessible leads before specifying this topology.

Protection functions and control features

Motor overload protection is integral — the unit monitors motor current and trips on overload without requiring an external overload relay. Intrinsic device protection covers the thyristors against over-temperature and over-current, and the adjustable current limitation lets you set the start current between 8% and 100% of the rated current. An external reset input is provided, allowing remote reset of the fault condition from a PLC or pushbutton station. The display shows fault codes directly on the unit, reducing troubleshooting time. A motor brake output is included as a product component — this can control a DC injection brake or mechanical brake coil without an additional interface relay.

Mounting, wiring, and clearance dimensions

The unit measures 640 mm high, 510 mm wide, and 290 mm deep. Fastening is by screw fixing (not DIN-rail clip) — the enclosure backplate must have drilled and tapped holes matching the mounting pattern. The mounting position allows vertical surface mounting with +/-90° rotation and +/-22.5° tilt forward/backward, giving flexibility in panel layout. Minimum clearance requirements: 100 mm above, 75 mm below, and 5 mm at the sides. Maximum motor cable length is 500 m — beyond this, capacitive charging current may cause nuisance tripping or thyristor misfiring. The pollution degree is 3 per IEC 60947-4-2, meaning the unit is suitable for industrial environments with conductive dust or occasional condensation.

Environmental limits and storage conditions

During operation, the ambient temperature must not exceed 60 °C. Storage temperature range is -25 to +80 °C — this applies to the unit in its original packaging, not installed in a panel. The product brand is SIRIUS, and the product designation is 'Soft starter' per the Siemens catalog.

MPN