Siemens 3RW4453-6BC34 — Soft Starters

Siemens 3RW4453-6BC34 SIRIUS Soft Starter, 954A, 690V

MPN3RW4453-6BC34

Siemens SIRIUS 3RW4453-6BC34 soft starter, 954 A at 40 °C, 690 V insulation voltage, integrated bypass, inside-delta wiring support, 115 V AC control supply.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW4453-6BC34 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW4453-6BC34 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C954A
Rated operational current at 50 °C856A
Rated operational current at 60 °C759A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%
3RW4453-6BC34 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz115V
Rated voltage at 60 Hz115V
Main circuit terminal typebusbar connection
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%
3RW4453-6BC34 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW4453-6BC34 — Mechanical
ParameterValue
Height640mm
Width510mm
Depth290mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm
3RW4453-6BC34 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

What the 954 A rating actually means for your motor line

The Siemens 3RW4453-6BC34 is a SIRIUS soft starter rated 954 A at 40 °C — that's the continuous motor current it can handle in standard in-line wiring. The 690 V insulation voltage gives headroom on 400/480 V systems without derating the isolation gap. An integrated bypass contact system means the thyristors are shorted out after the motor reaches full speed — the 954 A rating applies to the bypass path, not just the silicon. That keeps the heatsink cool in continuous run and extends the life of the semiconductors. Inside-delta wiring is supported, which drops the current through each thyristor leg to about 58% of the line current — effectively letting this unit start motors up to roughly 1650 A line current in a delta-configured winding. Check the motor terminal box arrangement before specifying that topology.

Panel fit and wiring — the physical constraints

This is a screw-fixed unit, not a DIN-rail snap-on. The footprint is 640 mm high × 510 mm wide × 290 mm deep — measure the backplate and door clearance before ordering. Required airflow gaps: 100 mm above, 75 mm below, and only 5 mm at the sides for tight side-by-side mounting. Main current circuit connects via busbars. The stranded cable range is 70 to 240 mm², with finely stranded (flexible) cable from 50 to 240 mm², and AWG equivalents from 2/0 to 500 kcmil. That's heavy lug work — budget for a hydraulic crimper and busbar drilling. Auxiliary and control circuits use screw-type terminals accepting 2 × (0.5 to 2.5 mm²) solid or 2 × (AWG 20 to 14) for aux contacts. Maximum motor cable length is 500 m — fine for most plant layouts, but if you're feeding a remote pump house, check the cable capacitance against the thyristor dV/dt rating.

Lifecycle and sourcing — still active, no replacement needed

Protection and control features — what's built in

Motor overload protection and intrinsic device protection are integrated — no separate overload relay needed, and the thyristor junction temperature is monitored directly. Adjustable current limitation lets you set the start current between 8% and 100% of the rated motor current, and the minimum load threshold is 8% — below that the unit won't regulate, but that's rarely an issue for induction motors. An external reset input allows remote fault clearing from a PLC or pushbutton station. The display version shows fault codes on the unit itself — no need to plug in a laptop for basic diagnostics. A motor brake output is included, which controls a DC injection brake for vertical or high-inertia loads — wire it to the brake coil directly. Control supply is 115 V AC at both 50 Hz and 60 Hz, with operating frequency rated 50 to 60 Hz. Storage temperature range is -25 to +80 °C; operating ambient max is 60 °C with derating applied above 40 °C.

Frequently asked questions

Where can I buy 3RW4453-6BC34?

This part is sourced through independent distribution channels. Submit an RFQ for current availability and pricing — both are confirmed at quote time.

Can 3RW4453-6BC34 be used for inside-delta configuration?

Yes — inside-delta wiring is supported. In that topology the current through each thyristor leg drops to roughly 58% of line current, allowing the unit to start motors with a higher line current than its in-line rating.

MPN
3RW4453-6BC34