Siemens 3RW4455-2BC45

Siemens 3RW4455-2BC45 SIRIUS Soft Starter, 1200 A, 690 V

MPN 3RW4455-2BC45

Siemens SIRIUS 3RW4455-2BC45 soft starter, 1200 A at 40 °C, 690 V insulation voltage, thyristor-based, integrated bypass contact system, screw fixing.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW4455-2BC45 specifications
ParameterValue
Mountingscrew fixing
Depth290 mm
Width510 mm
Height640 mm

Product details

Sizing the 3RW4455-2BC45 for motor starting duty

Insulation voltage is 690 V, certified to IEC 60947-4-2 with pollution degree 3 — the standard for industrial motor starting where conductive dust and condensation are present. The operating frequency covers 50... 60 Hz, so it lands on either line frequency without a configuration change. Thyristor-based switching with an integrated bypass contact system means the silicon handles the ramp-up, then the bypass contactor carries the full-load current continuously — the thyristors are only stressed during start/stop, not at steady state. Adjustable current limitation and motor overload protection are built in, so no separate overload relay is needed for the motor branch.

Panel integration and clearance constraints

Clearance requirements: 100 mm upwards, 75 mm downwards, and only 5 mm at the side — the side clearance is tight enough that adjacent components can sit nearly flush, but the vertical air path needs room for convection cooling. The derating curve assumes free air flow; stacking units without the vertical gap will push the operating temperature above the 60 °C ceiling. Main circuit wiring accepts stranded 70... 240 mm² or finely stranded 50... 240 mm², plus 2/0... 500 kcmil for North American builds.

Lifecycle and compliance documentation

The product carries pollution degree 3 per IEC 60947-4-2, which is the relevant product standard for soft starters. The insulation voltage rating of 690 V and the 50/60 Hz operating frequency are declared on the nameplate. For RoHS/REACH declarations, the manufacturer provides a declaration of conformity referenced to the SIRIUS series; request the current declaration at RFQ.

MPN
3RW4455-2BC45