Siemens 3RW4456-2BC35 — Soft Starters

Siemens 3RW4456-2BC35 SIRIUS Soft Starter, 1351A at 40°C

MPN3RW4456-2BC35

Siemens SIRIUS 3RW4456-2BC35 soft starter, 1351 A at 40 °C, 690 V insulation voltage, 50/60 Hz, integrated bypass, inside-delta capable, pollution degree 3, screw fixing.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW4456-2BC35 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW4456-2BC35 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C1 351A
Rated operational current at 50 °C1 200A
Rated operational current at 60 °C1 065A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%

Control & Connection

3RW4456-2BC35 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz115V
Rated voltage at 60 Hz115V
Main circuit terminal typebusbar connection
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%

Protection & Features

3RW4456-2BC35 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW4456-2BC35 — Mechanical
ParameterValue
Height640mm
Width510mm
Depth290mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm

Environmental

3RW4456-2BC35 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

What the 1351A rating means in your enclosure

The 3RW4456-2BC35: Insulation voltage rated 690 V gives headroom on 400/480/575 V systems, and the 50/60 Hz operating frequency means one unit covers both line frequencies globally.

Inside-delta wiring and bypass — what they save you

Inside-delta circuit capability lets you wire the thyristors inside the motor delta winding, reducing the current the soft starter must handle to 58% of the line-fed rating — a 1351 A line-rated starter covers a motor that would otherwise need a 2300 A unit in line configuration. Integrated bypass contact system means the thyristors are shorted out once the motor is at full speed — no external bypass contactor to buy, wire, or lose space for, and the heat load in the panel drops to the bypass contact resistance instead of the thyristor forward voltage drop.

Mounting, clearances, and wiring — what fits in the panel

Clearance requirements: 100 mm above for cable entry and airflow, 75 mm below, and only 5 mm at the sides — the side clearance is tight enough that adjacent units can be mounted side-by-side without a gap, but the vertical space is mandatory for the busbar connections and natural convection. Main circuit wiring accepts stranded 70-240 mm² or finely stranded 50-240 mm², or busbar connection — the busbar option is the cleanest for the 1351 A range, avoiding the bending radius and lug stack-up of parallel cables. Auxiliary and control circuit terminals are spring-loaded, accepting solid 0.25-1.5 mm² — tool-less insertion for PLC and relay signals, and the spring clamp holds under vibration better than screw terminals.

Protection layers and diagnostics

Motor overload protection, intrinsic device protection, and adjustable current limitation are all built in — the soft starter can replace a separate overload relay for most applications, and the current limit setting lets you cap inrush to protect driven machinery. Pollution degree 3 per IEC 60947-4-2 certifies the unit for industrial environments with conductive dust or occasional condensation — the creepage distances and enclosure sealing are designed for that severity level. A display for fault signals gives local diagnostic readout without a separate HMI or laptop — the first thing a technician looks at when the starter trips on a phase imbalance or over-temperature event. Motor brake output integrated means a brake motor can be controlled directly from the soft starter without a separate brake contactor — saves a panel component and the wiring between them.

Frequently asked questions

What is the maximum motor cable length for the 3RW4456-2BC35?

The maximum wire length is 500 m — beyond that, reflected wave voltage spikes at the motor terminals can exceed the winding insulation rating, especially on 480/575 V systems.

Does the 3RW4456-2BC35 include a bypass contactor?

Yes, the integrated bypass contact system shorts the thyristors in run mode — no external bypass contactor is needed, and the heat dissipation drops to the contact resistance level instead of the thyristor forward drop.

What compliance documentation does Siemens provide for the 3RW4456-2BC35?

The unit is certified to IEC 60947-4-2 for pollution degree 3, and carries the SIRIUS brand with full RoHS, REACH, and CE declarations available from Siemens — the declaration of conformity covers the 690 V insulation voltage and 50/60 Hz operating frequency.