Siemens 3RW4456-2BC36 SIRIUS Soft Starter, 1351 A, 690 V

MPN3RW4456-2BC36

Siemens SIRIUS 3RW4456-2BC36 soft starter, 1351 A at 40 °C, 690 V insulation, 50/60 Hz, integrated bypass, inside-delta capable, IP00.

StockContact for availability
Lead time1-2 Weeks wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW4456-2BC36 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW4456-2BC36 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C1 351A
Rated operational current at 50 °C1 200A
Rated operational current at 60 °C1 065A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%

Control & Connection

3RW4456-2BC36 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz115V
Rated voltage at 60 Hz115V
Main circuit terminal typebusbar connection
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%

Protection & Features

3RW4456-2BC36 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW4456-2BC36 — Mechanical
ParameterValue
Height640mm
Width510mm
Depth290mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm

Environmental

3RW4456-2BC36 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

Current rating that governs the real operating envelope

The 3RW4456-2BC36: The headline 1351 A at 40 °C is the rating at the manufacturer's derating temperature threshold — above that, the available current drops to 1200 A at 50 °C and 1065 A at 60 °C.

Integrated bypass — one less contactor in the BOM

The 3RW4456-2BC36 carries an integrated bypass contact system, meaning the thyristors are shorted out once the motor reaches full speed. This eliminates the external bypass contactor that a standard soft starter topology requires — saves one panel-mounted device, reduces wiring, and cuts the heat load inside the enclosure because the bypass carries the full-load current with negligible losses.

Inside-delta wiring cuts line current by 42 %

This soft starter supports inside-delta circuit connection, which places the thyristors in the motor delta legs rather than the supply lines. The line current seen by the upstream breaker and cable is 58 % of the motor FLA — a 1351 A motor draws roughly 784 A from the supply in inside-delta mode. That difference can drop the feeder cable by two AWG sizes and may keep the installation within an existing MCC bucket rating without a bus upgrade.

Pollution degree 3 — built for the panel floor, not the clean room

Rated pollution degree 3 per IEC 60947-4-2, the creepage distances and clearance are designed for conductive dust, humidity, and the general industrial atmosphere you find on a motor control centre floor. This is not a clean-room device; it holds the unit on the grid in the same environment where the MCC sees grinding dust and coolant mist, provided the enclosure keeps the internal ambient within the derating curve.

Protection set — three functions, one device

Motor overload protection, intrinsic device protection for the thyristor junction temperature, and adjustable current limitation are all integrated. The current limitation sets a ceiling on the starting inrush — useful when starting into a weak supply or when the upstream protection is coordinated for a specific let-through. The motor overload replaces a separate thermal overload relay in the line, provided the application is within the soft starter's operating range.

Control wiring — spring terminals, no torque driver needed

The spring clamp holds the conductor without periodic re-torquing — one less maintenance item on the PM schedule. Main circuit connections are busbar with stranded cable range 70... 240 mm² and finely stranded 50... 240 mm², or 2/0... 500 kcmil for the North American install.

Mounting position and cooling clearances

Mounting position allows vertical surface orientation with ±90° rotation and ±22.5° tilt front-to-back. The cooling clearances are 100 mm upwards, 75 mm downwards, and 5 mm at the sides — the side clearance is tight, so the real thermal bottleneck is the vertical air path. Stacking units without the vertical clearance will force the upper unit to operate on the 50 °C or 60 °C derating curve even if the room ambient is 40 °C.

MPN
3RW4456-2BC36