Siemens 3RW4457-2BC34 — Soft Starters

Siemens 3RW4457-2BC34 SIRIUS Soft Starter, 1,524 A, 690 V

MPN3RW4457-2BC34

Siemens SIRIUS 3RW4457-2BC34 soft starter, 1,524 A at 40 °C, 690 V insulation voltage, 50/60 Hz, integrated bypass contact system, inside-delta circuit, screw fixing, 640 x 510 x 290 mm.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW4457-2BC34 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW4457-2BC34 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C1 524A
Rated operational current at 50 °C1 351A
Rated operational current at 60 °C1 200A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%

Control & Connection

3RW4457-2BC34 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz115V
Rated voltage at 60 Hz115V
Main circuit terminal typebusbar connection
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%

Protection & Features

3RW4457-2BC34 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW4457-2BC34 — Mechanical
ParameterValue
Height640mm
Width510mm
Depth290mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm

Environmental

3RW4457-2BC34 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

Rated current and thermal derating — the real motor ceiling

The 3RW4457-2BC34 is rated 1,524 A at 40 °C ambient — that's the full-load current it can start and run continuously when the panel ambient stays at or below 40 °C. At 50 °C the ceiling drops to 1,351 A, and at 60 °C it's 1,200 A. If your enclosure runs hot — say a non-ventilated cabinet next to a motor — the derating curve is the number that governs the real motor size, not the 40 °C headline. The integrated bypass contact system shunts the thyristors out of the circuit once the motor reaches full speed. That means the heat dissipation in run mode is just the bypass contact resistance, not the semiconductor forward drop — so the derating matters less for continuous running than for the start cycle.

Inside-delta wiring and motor protection — what the terminals mean

This soft starter supports inside-delta circuit wiring, which connects the soft starter in series with each motor winding rather than in the supply lines. That reduces the current the soft starter sees to 58% of the line current — a 1,524 A rated unit can start a motor with a line FLA up to roughly 2,630 A when wired inside-delta. Motor overload protection and intrinsic device protection are built in — no separate overload relay needed. The adjustable current limitation lets you set the start current anywhere from 8% minimum load up to the rated ceiling, so you can tune the ramp for a soft start on a conveyor or a pump. The main circuit terminals are busbar connection, accepting stranded cable 70–240 mm² or finely stranded 50–240 mm². Auxiliary and control wiring lands on spring-loaded terminals — no screwdriver torque check needed, which saves time on a panel with dozens of control wires.

Mounting and integration into the panel

Mounting is screw fixing — not DIN-rail snap-on. The envelope is 640 mm high, 510 mm wide, 290 mm deep. Plan for 100 mm clearance above and 75 mm below for ventilation and cable bending radius; side clearance is 5 mm. The mounting position allows a vertical surface with ±90° rotation and ±22.5° tilt forward/back. That gives flexibility in a tight cabinet — you can orient the display for readability without relocating the whole assembly. Operating temperature range is 60 °C max during operation; storage range is -25 to +80 °C.

Frequently asked questions

What is the rated current of 3RW4457-2BC34 at different ambient temperatures?

At 40 °C ambient the rated current is 1,524 A. The 40 °C figure is the headline rating; the derated values govern the real motor size in a warm enclosure.

What compliance documentation does Siemens provide for 3RW4457-2BC34?

The soft starter carries a pollution degree 3 rating per IEC 60947-4-2 and an insulation voltage of 690 V. Standard Siemens documentation includes the declaration of conformity and the product manual; specific RoHS/REACH/UL certificates are available from Siemens support or your distributor upon request.