Siemens 3RW4457-2BC44 — Soft Starters

Siemens 3RW4457-2BC44 SIRIUS Soft Starter, 1524 A at 40°C

MPN3RW4457-2BC44

Siemens SIRIUS 3RW4457-2BC44 soft starter, 1524 A at 40 °C, 690 V insulation voltage, 50/60 Hz, integrated bypass contact system, inside-delta circuit, screw fixing, 640 x 510 x 290 mm.

StockIn Stock (45)
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026Stock-verified to date
How we verify every order →

Specifications

Identification

3RW4457-2BC44 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW4457-2BC44 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C1 524A
Rated operational current at 50 °C1 351A
Rated operational current at 60 °C1 200A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%

Control & Connection

3RW4457-2BC44 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz230V
Rated voltage at 60 Hz230V
Main circuit terminal typebusbar connection
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%

Protection & Features

3RW4457-2BC44 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW4457-2BC44 — Mechanical
ParameterValue
Height640mm
Width510mm
Depth290mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm

Environmental

3RW4457-2BC44 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

1524 A at 40 °C — the derating curve sets the real limit

The 3RW4457-2BC44: That figure drops to 1351 A at 50 °C and 1200 A at 60 °C — the derating is linear with temperature, so the panel ambient inside the enclosure, not the motor room temperature, governs the continuous current you can pass through the thyristors. Operating frequency is 50/60 Hz, control voltage 230 V at both line frequencies.

Integrated bypass and inside-delta wiring

An integrated bypass contact system closes after the start ramp, shunting the thyristors and eliminating semiconductor conduction losses during run. This means the 1524 A rating applies to the bypass path, not just the SCRs — the thermal load on the enclosure drops once the motor is at speed. Inside-delta circuit wiring is supported, which reduces the line-side current to 58% of the motor full-load current in a delta-connected motor. For a 1524 A motor FLC, the soft starter sees roughly 884 A per phase on the line side — a significant saving on upstream cable and contactor sizing.

Mounting, clearances, and conductor terminations

Screw fixing to a vertical mounting surface, with ±90° rotation and ±22.5° tilt forward/backward allowed. Dimensions: 640 mm height, 510 mm width, 290 mm depth — plan the enclosure backplate accordingly. Clearance requirements: 100 mm above, 75 mm below, 5 mm at the sides. These are the minimum air gaps for natural convection cooling and arc-flash containment per the installation guide. Main current circuit connection is via busbar (not cable lugs). Auxiliary and control circuits use spring-loaded terminals — no screw torque check needed on those.

Protection and control features

Motor overload protection is built in — no separate overload relay required. Adjustable current limitation lets you set the start current between 100% and the rated current ceiling, matching the motor inrush to the supply capacity. Minimum load detection threshold is 8% of the rated current — below that the soft starter may not detect the motor is connected. External reset input allows remote fault recovery without opening the panel door. A local display shows fault codes. Intrinsic device protection covers the thyristors against over-temperature and over-current. The pollution degree is 3 per IEC 60947-4-2 — suitable for industrial environments with conductive dust or occasional condensation.

Frequently asked questions

What is the maximum motor cable length for the 3RW4457-2BC44?

The maximum wire length from the soft starter to the motor is 500 m. This is the total cable run per phase, not the sum of all three phases — longer runs increase capacitive charging current and may cause nuisance trips on the thyristor gate drive.

Does the 3RW4457-2BC44 include a motor brake output?

Yes, a motor brake output is integrated as a product component. This allows direct control of a DC injection brake or mechanical brake coil without a separate contactor, simplifying the control wiring.

MPN
3RW4457-2BC44